Last Modified: 7-3-2017 |
6.8:8.0.40 |
Doc ID: RM000000V2A00CX |
|
Model Year Start: 2007 |
Model: LX470 |
Prod Date Range: [08/2006 -
] |
|
Title:
2UZ-FE COOLING: THERMOSTAT: INSPECTION; 2007 MY LX470 [08/2006 - ]
|
INSPECTION
1. INSPECT THERMOSTAT
HINT:
The valve opening temperature is inscribed on the thermostat.
(a) Immerse the thermostat in water and then gradually heat the water.
|
(b) Check the valve opening temperature of the thermostat.
Standard valve opening temperature:
80 to 84°C (176 to 183°F)
If the valve opening temperature is not within the specified range, replace the thermostat.
|
|
|
(c) Check the valve lift.
Standard valve lift:
10 mm (0.39 in.) or more at 95°C (203°F)
If the valve lift is not as specified, replace the thermostat.
|
|
(d) Check that the valve is fully closed when the thermostat temperature is below 40°C (104°F).
If not fully closed, replace the thermostat.
|