DTC
|
P2759
|
Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)
|
DESCRIPTION
The amount of current flow to the solenoid is controlled by the duty ratio* of the ECM output signal. The higher the duty ratio becomes, the higher the lock-up hydraulic pressure becomes during the lock-up operation.
*: The duty ratio is the ratio of the current ON time (A) to the total of the current ON and OFF times (A + B).
Duty Ratio (%) = A / (A + B) x 100
|
DTC No.
|
DTC Detection Condition
|
Trouble Area
|
|
P2759
|
Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1 trip detection logic)
|
-
Open or short in shift solenoid valve SLU circuit
-
Shift solenoid valve SLU
-
ECM
|
|
1. Reference: Inspect using an oscilloscope.
Check the waveform of the ECM connector.
Standard voltage:
Refer to illustration.
|
Item
|
Content
|
|
Tester Connection
|
E7-15 (SLU+) - E7-14 (SLU-)
|
|
Tool Setting
|
5 V/DIV., 1 msec./DIV.
|
|
Condition
|
4th (lock-up) or 5th (lock-up) gear
|
|
|
MONITOR DESCRIPTION
When an open or short in a shift solenoid valve SLU circuit is detected, the ECM determines that there is a malfunction. The ECM will illuminate the MIL and store this DTC.
MONITOR STRATEGY
|
Related DTCs
|
P2759: Shift solenoid valve SLU/Range check
|
|
Required sensors/Components
|
Shift solenoid valve SLU
|
|
Frequency of operation
|
Continuous
|
|
Duration
|
1 sec.
|
|
MIL operation
|
Immediate
|
|
Sequence of operation
|
None
|
TYPICAL ENABLING CONDITIONS
All
|
The monitor will run whenever this DTC is not present.
|
None
|
Case 1
|
Solenoid current cut status
|
Not cut
|
|
Battery voltage
|
11 V or more
|
|
Ignition switch
|
ON
|
|
Starter
|
OFF
|
Case 2
|
Battery voltage
|
8 V or more
|
|
Ignition switch
|
ON
|
|
Starter
|
OFF
|
TYPICAL MALFUNCTION THRESHOLDS
Case 1
|
Solenoid status (SLU) from IC
|
Fail (open or short)
|
Case 2
COMPONENT OPERATING RANGE
|
Output signal duty
|
Less than 100%
|
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
|
1.
|
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)
|
|
(a) Disconnect the E1 wire connector.
|
|
(b) Measure the resistance of the transmission wire.
Standard resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
13 (SLU+) - 5 (SLU-)
|
20°C (68°F)
|
5.0 to 5.6 Ω
|
|
13 (SLU+) - Body ground
|
20°C (68°F)
|
10 kΩ or higher
|
|
5 (SLU-) - Body ground
|
20°C (68°F)
|
10 kΩ or higher
|
| OK |
|
|
|
2.
|
CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM)
|
|
(a) Disconnect the E7 ECM connector.
|
|
(b) Measure the resistance of the wire harness side connector.
Standard resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
E7-15 (SLU+) - E7-14 (SLU-)
|
20°C (68°F)
|
5.0 to 5.6 Ω
|
|
E7-15 (SLU+) - Body ground
|
20°C (68°F)
|
10 kΩ or higher
|
|
E7-14 (SLU-) - Body ground
|
20°C (68°F)
|
10 kΩ or higher
|
| NG |
|
REPAIR OR REPLACE HARNESS AND CONNECTOR
|
| OK |
|
REPLACE ECM
|
|
3.
|
INSPECT SHIFT SOLENOID VALVE SLU
|
|
(a) Remove the shift solenoid valve SLU.
(b) Measure the resistance of the solenoid valve.
Standard resistance:
5.0 to 5.6 Ωat 20°C (68°F)
(c) Connect the battery's positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
OK:
Solenoid makes operating noise.
|
|
| NG |
|
REPLACE SHIFT SOLENOID VALVE SLU
|
| OK |
|
REPAIR OR REPLACE TRANSMISSION WIRE
|
|