Last Modified: 7-3-2017 6.8:8.0.40 Doc ID: RM000000YDB00UX
Model Year Start: 2007 Model: LX470 Prod Date Range: [08/2006 -           ]
Title: 2UZ-FE ENGINE CONTROL SYSTEM: SFI SYSTEM: P0116; Engine Coolant Temperature Circuit Range / Performance Problem; 2007 MY LX470 [08/2006 -        ]

DTC

P0116

Engine Coolant Temperature Circuit Range / Performance Problem

DESCRIPTION

Refer to DTC P0115 2007 MY LX470 [08/2006 -        ]; 2UZ-FE ENGINE CONTROL SYSTEM: SFI SYSTEM: P0115,P0117,P0118; Engine Coolant Temperature Circuit+ .

DTC No.

DTC Detection Condition

Trouble Area

P0116

When either of following conditions met (2 trip detection logic):

  • When cold engine started and engine warmed up, Engine Coolant Temperature (ECT) sensor value does not change.
  • After warmed up engine stopped and then next cold engine start performed, ECT sensor value does not change.
  • Thermostat
  • Engine Coolant Temperature (ECT) sensor

MONITOR DESCRIPTION

ECT sensor cold start monitor

When a cold engine start is performed and then the engine is warmed up, if the ECT sensor value does not change, it is determined that a malfunction has occurred. If this is detected in 2 consecutive driving cycles, the MIL is illuminated and a DTC is set.

ECT sensor soak monitor

If the ECT sensor value does not change after the warmed up engine is stopped and then the next cold engine start is performed, it is determined that a malfunction has occurred. If this is detected in 2 consecutive driving cycles, the MIL is illuminated and a DTC is set.

MONITOR STRATEGY

Related DTCs

P0116: Engine Coolant Temperature (ECT) sensor stuck (low ECT)

P0116: ECT sensor stuck (high ECT)

Required Sensors/Components (Main)

Engine Coolant Temperature sensor

Required Sensors/Components (Related)

Crankshaft position sensor, IAT sensor, MAF meter

Frequency of Operation

Once per driving cycle

Duration

1 second

MIL Operation

2 driving cycles

Sequence of Operation

None

TYPICAL ENABLING CONDITIONS

Monitor will run whenever these DTCs are not present

P0100 - P0103 (MAF sensor)

Cold start monitor:

Battery voltage

10.5 V or more

Time after engine start

1 second or more

ECT at engine start

Less than 60°C (140°F)

IAT sensor circuit

Not fail

Soak time

0 seconds or more

Accumulated MAF

2,157 g or more

Fuel cut

OFF

Difference between ECT at engine start and IAT

Less than 40°C (72°F)

Soak monitor:

Battery voltage

10.5 V or more

Engine

Running

IAT sensor circuit

Not fail

Soak time

5 hours or more

ECT

60°C (140°F) or more

Accumulated MAF

4,202 g or more

TYPICAL MALFUNCTION THRESHOLDS

Cold start monitor:

Engine coolant temperature change

Less than 5°C (9°F)

Soak monitor:

Difference between current ECT sensor value and previous ECT sensor value when engine stopped

Less than 5°C (9°F)

COMPONENT OPERATING RANGE

Engine coolant temperature

Varies with actual engine coolant temperature

WIRING DIAGRAM

Refer to DTC P0115 2007 MY LX470 [08/2006 -        ]; 2UZ-FE ENGINE CONTROL SYSTEM: SFI SYSTEM: P0115,P0117,P0118; Engine Coolant Temperature Circuit+ .

INSPECTION PROCEDURE

HINT:

  • If DTC P0115, P0116, P0117, P0118 and P0125 are output simultaneously, the ECT sensor circuit may be open or shorted. Perform the troubleshooting of DTC P0115, P0117 or P0118 first.
  • Read freeze frame data using the intelligent tester. Freeze frame data records the engine conditions when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was running or stopped, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.

PROCEDURE

1.

CHECK OTHER DTC OUTPUT (IN ADDITION TO DTC P0116)

(a) Connect the intelligent tester to the CAN VIM. Then connect the CAN VIM to the DLC3.

(b) Turn the ignition switch ON.

(c) Enter the following menus: DIAGNOSIS / ENHANCED OBD II / DTC INFO / CURRENT CODES.

(d) Read the DTCs.

Display (DTC output)

Proceed to

P0116

A

P0116 and other DTCs

B

B

GO TO RELEVANT DTC CHART

A

2.

INSPECT THERMOSTAT

(a) Remove the thermostat 2007 MY LX470 [08/2006 -        ]; 2UZ-FE COOLING: THERMOSTAT: REMOVAL .

(b) Check the valve opening temperature of the thermostat.

OK:

80 to 84°C (176 to 183°F)

HINT:

In addition to the above check, confirm that the valve is completely closed when the temperature is below the standard.

(c) Reinstall the thermostat 2007 MY LX470 [08/2006 -        ]; 2UZ-FE COOLING: THERMOSTAT: INSTALLATION .

NG

REPLACE THERMOSTAT

OK

REPLACE ENGINE COOLANT TEMPERATURE SENSOR