(a) Measure the resistance between the terminals.
Standard resistance:
|
Temperature
|
Specified Condition
|
|
Cold
|
1,630 to 2,740 Ω
|
|
Hot
|
2,065 to 3,225 Ω
|
NOTICE:
In the table above, the terms "cold" and "hot" refer to the temperature of the coils. "Cold" means approximately -10 to 50°C (14 to 122°F). "Hot" means approximately 50 to 100°C (122 to 212°F).
If the result is not as specified, replace the sensor.
|
|