Last Modified: 7-3-2017 |
6.8:8.0.40 |
Doc ID: RM0000017XD006X |
|
Model Year Start: 2007 |
Model: LX470 |
Prod Date Range: [08/2006 -
] |
|
Title:
2UZ-FE EMISSION CONTROL: AIR PUMP: INSPECTION; 2007 MY LX470 [08/2006 - ]
|
INSPECTION
1. INSPECT AIR PUMP
|
(a) Connect the positive (+) lead from the battery to terminal 1 and negative (-) lead to terminal 2, and check that air flows.
If operation is not as specified, replace the air pump.
|
|
2. INSPECT AIR SWITCHING VALVE
|
(a) Blow air into port A and check that air is not discharged from port B.
|
|
|
(b) Apply battery voltage across the terminals.
|
|
(c) Blow air into port A and check that air is discharged from port B.
If operation is not as specified, replace the air switching valve.
3. INSPECT NO. 2 AIR SWITCHING VALVE
|
(a) Blow air into port B and check that air is not discharged from port C.
|
|
|
(b)
Apply vacuum of 30 kPa (306 gf/cm
2
, 4.35 psi) to port A, blow air into port B and check that air is discharged from port C.
If operation is not as specified, replace the No. 2 air switching valve.
|
|
|