(a) Without disconnecting the power seat position sensor's connector, measure the voltage between terminal O/P of the sensor and body ground.
Standard voltage:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
A2-4 (O/P) - Body ground
|
Motor stopped (Check several times with the motor in a different position each time)
|
0 V or 8 V according to stop position
|
|
A2-4 (O/P) - Body ground
|
With motor turning
|
Alternating between 8 V and below 1 V
|
|
B2-4 (O/P) - Body ground
|
Motor stopped (Check several times with the motor in a different position each time)
|
0 V or 8 V according to stop position
|
|
B2-4 (O/P) - Body ground
|
With motor turning
|
Alternating between 8 V and below 1 V
|
|
|