(a) Remove the air inlet servo motor.
(b) Connect positive (+) lead to terminal 5 (MREC) and negative (-) lead to terminal 4 (MFRS), and check the air inlet damper control servo motor.
OK:
The lever moves smoothly to REC position.
(c) Connect positive (+) lead to terminal 4 (MFRS) and negative (-) lead to terminal 5 (MREC), and check the air inlet damper control servo motor.
OK:
The lever moves smoothly to FRS position.
|