STEERING POS1
|
Steering sensor 1 reading / min.: -1862 deg, 1877 deg
|
-1682 to 1877 deg
|
Turning the steering wheel changes the value
|
|
STEERING POS2
|
Steering sensor 1 reading / min.: -1862 deg, 1877 deg
|
-1682 to 1877 deg
|
Turning the steering wheel changes the value
|
|
STR SENS1
|
Steering sensor 1 / HIGH or LOW
|
High or Low
|
Turning the steering switches value to high or low
|
|
STR SENS2
|
Steering sensor 2/ HIGH or LOW
|
High or Low
|
Turning the steering switches value to high or low
|
|
STR SENS3
|
Steering sensor 3/ HIGH or LOW
|
High or Low
|
Turning the steering switches value to high or low
|
|
SPD (VSC)
|
Speed sensor reading / min.: 0 km/h, max.: 255 km/h
|
Actual vehicle speed
|
Speed indicated on speedometer
|
|
WHEEL SPD RR
|
Wheel speed sensor (RR) reading / min.: 0 km/h, max.: 255 km/h
|
Actual vehicle speed
|
Speed indicated on speedometer
|
|
WHEEL SPD RL
|
Wheel speed sensor (RL) reading / min.: 0 km/h, max.: 255 km/h
|
Actual vehicle speed
|
Speed indicated on speedometer
|
|
ENGINE REV (RPM)
|
Revolution sensor / LESS 300 or MORE 300
|
Less than 300
|
Engine stop
|
|
More than 300
|
Engine running
|
|
MTR SOU CUR
|
Motor power source actual current / min.: 0 A, max.: 127.5 A
|
Less than 10 A
|
When not turning the steering wheel
|
|
Less than 60 A
|
When turning the steering wheel
|
|
MTR SOU CUR EST
|
Estimated motor power source actual current / min.: 0 A, max.: 127.5 A
|
Less than 10 A
|
When not turning the steering wheel
|
|
Less than 60 A
|
When turning the steering wheel
|
|
PIG SOURCE VOL
|
PIG source voltage / min.: 0 V, max.: 22.5 V
|
9 to 16 V
|
Ignition switch ON (Engine stop)
|
|
IG SOURCE VOL
|
IG source voltage / min.: 0 V, max.: 22.5 V
|
9 to 16 V
|
Ignition switch ON (Engine stop)
|
|
MTR CUR EST
|
Motor estimation current / min.: 0 A, max.: 127.5 A
|
Less than 10 A
|
When not turning the steering wheel
|
|
Less than 60 A
|
When turning the steering wheel
|
|
TERMINAL VOL U
|
Terminal voltage U / min.: 0 V, max.: 25.5 V
|
0 to 16 V
|
Turning the steering wheel changes the value (When the engine running and VGRS system operates)
|
|
TERMINAL VOL V
|
Terminal voltage V / min.: 0 V, max.: 25.5 V
|
0 to 16 V
|
Turning the steering wheel changes the value (When the engine running and VGRS system operates)
|
|
TERMINAL VOL W
|
Terminal voltage W / min.: 0 V, max.: 25.5 V
|
0 to 16 V
|
Turning the steering wheel changes the value (When the engine running and VGRS system operates)
|
|
ACTUATOR POS
|
Actuator position / min.: -286 deg, max.: 288 deg
|
-286 to 288 deg
|
Turning the steering wheel changes the value (When the engine running and VGRS warning light goes off)
|
|
MTR REV ANG U
|
Motor revolution angle sensor output U HIGH or LOW
|
High or Low
|
Turning the steering wheel changes the value (When the engine running and VGRS warning light goes off)
|
|
MTR REV ANG V
|
Motor revolution angle sensor output V HIGH or LOW
|
High or Low
|
Turning the steering wheel changes the value (When the engine running and VGRS warning light goes off)
|
|
MTR REV ANG W
|
Motor revolution angle sensor output W HIGH or LOW
|
High or Low
|
Turning the steering wheel changes the value (When the engine running and VGRS warning light goes off)
|
|
STR ANG VEL
|
Steering wheel angle velocity / min.: -1862 deg, max.: 1877 deg / sec.
|
-1862 to 1877 deg / sec.
|
Turning the steering wheel changes the value (When the engine running and VGRS warning light goes off)
|
|
LOCK OUTPUT VOL
|
Lock motor output voltage / min.: 0 V, max.: 22.5V
|
9 to 16 V
|
Ignition switch ON (Engine stop)
|
|
THERMISTOR TEMP
|
Thermistor temperature / min.: -50 °C, max.: 205°C
|
-50 to 205°C
|
When the VGRS system operates
|
|
ACT TARGET ANGL
|
Actuator target angle / min.: -286 deg, max.: 288 deg
|
-286 to 288 deg
|
When the VGRS system operates
|
|
ACT REV SPD
|
Actuator revolution speed / min.: -1862 deg / sec., max.: 1877 deg / sec.
|
-1862 to 1877 deg / sec.
|
When the VGRS system operates
|
|
DUTY VAL
|
Command value DUTY for actuator lock control / min.: 0 %, max.: 100 %
|
0 to 100 %
|
When the VGRS system operates
|
|
LOCK DUTY VAL
|
Command value DUTY / min.: 0 %, max.: 100 %
|
Less than 10 %
|
Ignition switch ON
|
|
STRAIGHT ANG FLG *1
|
Straight steering angle valid flag / INVALID or VALID
|
VALID or INVALID
|
Immediately after connecting the battery terminal
|
|
ACT DEV ANGL
|
Actuator deviation angle / min.: -286 deg, max.: 288 deg
|
-286 to 288 deg
|
When the VGRS system operates
|
|
ACT TEMP EST
|
Actuator estimation temperature: min.: -50°C, max.: 205°C
|
-50 to 205°C
|
When the VGRS system operates
|
|
MTR OVERHEAT *2
|
Record of continuous overheat preventive control / Rec or Unrec
|
Rec or Unrec
|
-
|
|
MTR LOW POWER *2
|
Record of low motor power source voltage / Rec or Unrec
|
Rec or Unrec
|
-
|
|
MTR HIGH POWER
|
Record of high motor power source voltage / Rec or Unrec
|
Rec or Unrec
|
-
|
|
FLO MALFUNCTION
|
Record of wheel speed malfunction (left) / Rec or Unrec
|
Rec or Unrec
|
-
|
|
FRO MALFUNCTION
|
Record of wheel speed malfunction (right) / Rec or Unrec
|
Rec or Unrec
|
-
|
|
TEST MODE
|
Test mode / NORMAL or TEST
|
NORMAL : Normal mode
TEST : During test mode
|
-
|
|
#CODES
|
Number of DTC recorded / min.: 0, max.: 255
|
Min.: 0, max.: 39
|
-
|