Last Modified: 7-3-2017 |
6.8:8.0.40 |
Doc ID: RM0000018PK005X |
|
Model Year Start: 2007 |
Model: LX470 |
Prod Date Range: [08/2006 -
] |
|
Title:
AIR CONDITIONING: FRONT HEATER UNIT: INSTALLATION; 2007 MY LX470 [08/2006 - ]
|
INSTALLATION
1. INSTALL HEATER UNIT
|
(a) Install the heater unit with the 4 nuts.
|
|
(b) Connect the connector.
|
(c) Install the lower defroster nozzle.
|
|
2. INSTALL FRONT COOLING UNIT
3. INSTALL INSTRUMENT PANEL AND REINFORCEMENT
4. CONNECT WATER HOSE
|
(a) Connect the water hoses to the heater radiator pipes and attach the clips.
HINT:
-
Push the water hose onto the heater radiator pipe to the second ridge on the pipe.
-
Install a hose clip in the position as shown in the illustration.
|
|
5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
6. PERFORM INITIALIZATION
(a)
Perform initialization
.
NOTICE:
Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.
7. CHECK SRS WARNING LIGHT
(a)
Check the SRS warning light
.
8.
ADD ENGINE COOLANT
9.
WARM UP ENGINE
10.
CHECK FOR ENGINE COOLANT LEAKS
|