ACTUATOR CHECK

1. ACTUATOR CHECK

(a) After entering the sensor check mode, press the R/F switch.

(b) Since each damper, motor and relay automatically operates at 1 second intervals beginning in order from 20 in the temperature display, check the temperature and air flow visually and manually.

If a slower display is desired, press the DEF switch and change it to step operation. Every time the DEF switch is pressed, the display changes by 1 step.

HINT:

  • The buzzer sounds when the display trouble code changes.
  • Codes are displayed in order from the smaller to the larger numbers.
  • To cancel the check mode, press the OFF switch.

Step No.

Display Code

Condition

Blower Motor

Air Flow Vent

Air Inlet Damper

Magnetic Clutch

Air Mix Damper

Rr. Heater Blower Motor

1

0

OFF

FACE

FRESH

OFF

Cool side (0% open)

OFF

2

1

LO

3

2

MED

R/F (50% open)

ON

LO

4

3

BI-LEVEL

RECIRC

Cool / Hot (50% open)

5

4

FOOT

FRESH

6

5

Hot side (100% open)

HI

7

6

FOOT/DEF

8

7

HI

DEF