Last Modified: 7-3-2017 |
6.8:8.0.40 |
Doc ID: RM000001CFW004X |
|
Model Year Start: 2007 |
Model: LX470 |
Prod Date Range: [08/2006 -
] |
|
Title:
AIR CONDITIONING: AIR CONDITIONING SYSTEM: ACTUATOR CHECK; 2007 MY LX470 [08/2006 - ]
|
ACTUATOR CHECK
1. ACTUATOR CHECK
|
(a) After entering the sensor check mode, press the R/F switch.
|
|
(b) Since each damper, motor and relay automatically operates at 1 second intervals beginning in order from 20 in the temperature display, check the temperature and air flow visually and manually.
If a slower display is desired, press the DEF switch and change it to step operation. Every time the DEF switch is pressed, the display changes by 1 step.
HINT:
-
The buzzer sounds when the display trouble code changes.
-
Codes are displayed in order from the smaller to the larger numbers.
-
To cancel the check mode, press the OFF switch.
|
Step No.
|
Display Code
|
Condition
|
|
Blower Motor
|
Air Flow Vent
|
Air Inlet Damper
|
Magnetic Clutch
|
Air Mix Damper
|
Rr. Heater Blower Motor
|
|
1
|
0
|
OFF
|
FACE
|
FRESH
|
OFF
|
Cool side (0% open)
|
OFF
|
|
2
|
1
|
LO
|
↑
|
↑
|
↑
|
↑
|
↑
|
|
3
|
2
|
MED
|
↑
|
R/F (50% open)
|
ON
|
↑
|
LO
|
|
4
|
3
|
↑
|
BI-LEVEL
|
RECIRC
|
↑
|
Cool / Hot (50% open)
|
↑
|
|
5
|
4
|
↑
|
FOOT
|
FRESH
|
↑
|
↑
|
↑
|
|
6
|
5
|
↑
|
↑
|
↑
|
↑
|
Hot side (100% open)
|
HI
|
|
7
|
6
|
↑
|
FOOT/DEF
|
↑
|
↑
|
↑
|
↑
|
|
8
|
7
|
HI
|
DEF
|
↑
|
↑
|
↑
|
↑
|
|