1. INSPECT FRONT HEIGHT CONTROL SENSOR SUB-ASSEMBLY
(a) Disconnect the height control sensor connector.
(b) Remove the height control sensor.
(c) Connect 3 dry batteries of 1.5 V in series.
(d) Connect terminal 2 to the batteries' positive (+) terminal, and terminal 3 to the batteries' negative (-) terminal, then apply voltage about 4.5 V between terminals 2 and 3.
(e) Measure the voltage between terminals 1 and 3, when the height control sensor link is slowly moved up and down.
Standard voltage:
|
Sensor Link Position
|
Voltage
|
|
Max. HI
|
Approx. 4.05 V
|
|
N
|
Approx. 2.25V
|
|
Min. LO
|
Approx. 0.45V
|
|