Last Modified: 7-3-2017 6.8:8.0.40 Doc ID: RM000001WPH00EX
Model Year Start: 2007 Model: LX470 Prod Date Range: [08/2006 -           ]
Title: 2UZ-FE ENGINE CONTROL SYSTEM: SFI SYSTEM: P0111; Intake Air Temperature Sensor Gradient Too High; 2007 MY LX470 [08/2006 -        ]

DTC

P0111

Intake Air Temperature Sensor Gradient Too High

DESCRIPTION

  • The Intake Air Temperature (IAT) sensor, mounted on the Mass Air Flow (MAF) meter, monitors the IAT. The IAT sensor has a built-in thermistor with a resistance that varies according to the temperature of the intake air. When the IAT is low, the resistance of the thermistor increases. When the temperature is high, the resistance drops. These variations in resistance are transmitted to the ECM as voltage changes (see Fig. 1).
  • The IAT sensor is powered by a 5 V supply from the THA terminal of the ECM, via resistor R.
  • Resistor R and the IAT sensor are connected in series. When the resistance value of the IAT sensor changes, the voltage at terminal THA also varies accordingly. Based on this signal, the ECM increases the fuel injection volume when the engine is cold to improve driveability.

DTC No.

DTC Detection Condition

Trouble Area

P0111

When either condition below is met:

  1. The intake air temperature rise is large, from the previous trip warm-up to the following trip (2 trip detection logic).
  2. When the change in the intake air temperature after engine start is less than the threshold value.

Mass air flow meter

MONITOR DESCRIPTION

The ECM performs OBD II monitoring based on the values from the intake air temperature sensor. If there is no change in the sensor value within the normal range, the ECM will not be able to perform OBD II monitoring or will misdiagnose that there is a malfunction in the sensor. The ECM detects the stuck intake air temperature sensor value by performing monitoring after the ignition switch is turned OFF or after the engine is started (short soak or long soak).

MONITOR STRATEGY

Related DTCs

P0111: Intake air temperature sensor rationality (After engine stop)

P0111: Intake air temperature sensor rationality (After cold engine start)

Required Sensors/Components (Main)

Intake Air Temperature (IAT) sensor

Required Sensors/Components (Sub)

-

Frequency of Operation

Once per driving cycle

Duration

5 hours or more

MIL Operation

2 driving cycles

Sequence of Operation

None

TYPICAL ENABLING CONDITIONS

All:

Monitor runs whenever following DTCs are not present

None

After engine stop:

Time after engine start

10 seconds or more

Battery voltage

10.5 V or more

ECT sensor circuit

OK

ECT change since engine

Less than 180°C (356°F)

ECT before engine stop

70°C (158°F) or more

Time that MAF is low before engine stop

70 minutes

Accumulated MAF amount before engine stop

1,893 g (66.8 oz.) or more

Key-off duration

30 minutes

After cold engine start:

Key-off duration

5 hours

Time after engine start

10 seconds or more

ECT sensor circuit

OK

ECT

70°C (158°F) or more

Accumulated MAF amount

1,893 g (66.8 oz.) or more

Either of the following conditions 1 or 2 is met:

-

1. Duration while engine load is low

120 seconds or more

2. Duration while engine load is high

10 seconds or more

TYPICAL MALFUNCTION THRESHOLDS

After engine stop:

IAT change

Less than 1°C (2°F)

After cold engine start:

IAT change

Less than 1°C (2°F)

WIRING DIAGRAM

Refer to DTC P0110 2007 MY LX470 [08/2006 -        ]; 2UZ-FE ENGINE CONTROL SYSTEM: SFI SYSTEM: P0110,P0112,P0113; Intake Air Temperature Circuit+ .

INSPECTION PROCEDURE

PROCEDURE

1.

CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0111)

(a) Connect the intelligent tester to the DLC3.

(b) Turn the ignition switch ON.

(c) Turn the tester ON.

(d) Enter the following menus: DIAGNOSIS / ENHANCED OBD II / DTC INFO / CURRENT CODES.

(e) Read DTCs.

Display (DTC Output)

Proceed to

P0111 and other DTCs

A

P0111

B

HINT:

If any DTCs other than P0111 are output, troubleshoot those DTCs first.

B

REPLACE MASS AIR FLOW METER

A

GO TO DTC CHART