Title: 2UZ-FE ENGINE CONTROL SYSTEM: SFI SYSTEM: P2420; Evaporative Emission System Switching Valve Control Circuit High; 2007 MY LX470 [08/2006 -        ]

DTC

P2420

Evaporative Emission System Switching Valve Control Circuit High

DTC SUMMARY

DTC

Monitoring Item

Malfunction Detection Condition

Trouble Area

Detection Timing

Detection Logic

P2420

Vent valve stuck open (vent)

Following condition met during key-off EVAP monitor:

  • EVAP pressure change when vent valve closed (ON) less than 0.3 kPa-g (2.25 mmHg-g)
  • Canister pump module (Reference orifice, leak detection pump, vent valve)
  • Connector/wire harness (Canister pump module - ECM)
  • ECM

While ignition switch OFF

2 trip

HINT:

The vent valve is built into the canister pump module.

DESCRIPTION

The description can be found in the EVAP (Evaporative Emission) System 2007 MY LX470 [08/2006 -        ]; 2UZ-FE ENGINE CONTROL SYSTEM: SFI SYSTEM: EVAP System+ .

INSPECTION PROCEDURE

Refer to the EVAP System 2007 MY LX470 [08/2006 -        ]; 2UZ-FE ENGINE CONTROL SYSTEM: SFI SYSTEM: EVAP System+ .

MONITOR DESCRIPTION

5 hours* after the ignition switch is turned OFF, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:

*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned OFF, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned OFF, the monitor check starts 2.5 hours later.

Sequence

Operation

Description

Duration

-

ECM activation

Activated by soak timer 5, 7 or 9.5 hours after ignition switch turned OFF.

-

A

Atmospheric pressure measurement

Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure.

If pressure in EVAP system not between 76 kPa-a and 110 kPa-a (570 mmHg-a and 825 mmHg-a), ECM cancels EVAP system monitor.

10 seconds

B

First reference pressure measurement

In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.

60 seconds

C

EVAP system pressure measurement

Vent valve turned ON (closed) to shut EVAP system.

Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured.

Write down measured value as it will be used in leak check.

If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.

15 minutes *

D

Purge VSV monitor

Purge VSV opened and then EVAP system pressure measured by ECM.

Large increase indicates normality.

10 seconds

E

Second reference pressure measurement

After second reference pressure measurement, leak check performed by comparing first and second reference pressure.

If stabilized system pressure higher than second reference pressure, ECM determines that EVAP system leaking.

60 seconds

-

Final check

Atmospheric pressure measured and then monitoring result recorded by ECM.

-

*: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

Vent valve stuck open (vent)

In operation C, the vent valve turns ON (closes) and the EVAP system pressure is then measured by the ECM, using the canister pressure sensor, to conduct an EVAP leak check. If the pressure does not increase when the vent valve is open, the ECM interprets this as the vent valve being stuck open. The ECM illuminates the MIL and sets the DTC.

MONITOR STRATEGY

Required Sensors/Components

Purge VSV and canister pump module

Frequency of Operation

Once per driving cycle

Duration

Within 2 minutes (varies with amount of fuel in tank)

MIL Operation

2 driving cycles

Sequence of Operation

None

TYPICAL ENABLING CONDITIONS

Enable conditions of EVAP key-OFF monitor

P043E (Reference orifice - low flow)

P043F (Reference orifice - high flow)

P0441 (Purge VSV - stuck open)

P0441 (Purge VSV - stuck close)

P0451 (Canister pressure sensor - noise)

P0455 (EVAP gross leak)

P0456 (EVAP small leak)

P2401 (Leak detection pump - stuck OFF)

P2402 (Leak detection pump - stuck ON)

P2419 (Vent valve - stuck ON)

P2420 (Vent valve - stuck OFF)

Atmospheric pressure

70 to 110 kPa-a (525 to 825 mmHg-a)

Battery voltage

10.5 V or higher

Vehicle speed

Less than 2.5 mph (4 km/h)

Ignition switch

OFF

Time after key off

5 or 7 or 9.5 hours

Canister pressure sensor malfunction (P0450, P0452, P0453)

Not detected

Purge VSV

Not operated by scan tool

Vent valve

Not operated by scan tool

Leak detection pump

Not operated by scan tool

Both of the following conditions 1 and 2 are met before key off

-

1. Duration that vehicle has been driven

5 minutes or more

2. EVAP purge operation

Performed

ECT

4.4 to 35°C (40 to 95°F)

IAT

4.4 to 35°C (40 to 95°F)

1. Key-off monitor sequence 1 to 8

1. Atmospheric pressure measurement

Next sequence is run if the following condition is met

-

Atmospheric pressure change

Less than 0.3 kPa-g (2.25 mmHg-g) in 1 second

2. First reference pressure measurement

Next sequence is run if the following conditions are met

-

EVAP pressure just after reference pressure measurement start

-1 kPa-g (-7.5 mmHg-g) or lower

Reference pressure

-4.85 to -1.05 kPa-g (-36.4 to -7.93 mmHg-g)

Reference pressure

Saturated within 60 seconds

3. Vent valve stuck closed check

Next sequence is run if the following condition is met

-

EVAP pressure change after vent valve is ON

0.3 kPa-g (2.25 mmHg-g) or more

4. Vacuum introduction

Next sequence is run if the following condition is met

-

EVAP pressure

Saturated within 15 minutes

5. Purge VSV stuck closed check

Next sequence is run if the following condition is met

-

EVAP pressure change after purge valve is open

0.3 kPa-g (2.25 mmHg-g) or more

6. Second reference pressure measurement

Next sequence is run if the following conditions are met

-

EVAP pressure just after reference pressure measurement start

-1 kPa-g (-7.5 mmHg-g) or lower

Reference pressure

-4.85 to -1.05 kPa-g (-36.4 to -7.93 mmHg-g)

Reference pressure

Saturated within 60 seconds

Difference between first reference pressure and second reference pressure

Less than 0.7 kPa-g (5.25 mmHg-g)

7. Leak check

Next sequence is run if the following condition is met

-

EVAP pressure when vacuum introduction is complete

Second reference pressure or lower

8. Atmospheric pressure measurement

EVAP monitor is complete if the following condition is met

-

Atmospheric pressure difference between sequence 1 and 8

Within 0.3 kPa-g (2.25 mmHg-g)

TYPICAL MALFUNCTION THRESHOLDS

EVAP pressure change after EVAP canister vent valve ON

Less than 0.3 kPa-g (2.25 mmHg-g)

MONITOR RESULT

Refer to detailed information on EVAP system 2007 MY LX470 [08/2006 -        ]; 2UZ-FE ENGINE CONTROL SYSTEM: SFI SYSTEM: EVAP System+ .