Home Vehicle Interior Supplemental Restraint Systems OCCUPANT CLASSIFICATION SYSTEM
Last Modified: 11-27-2007 1.6 U
Service Category: Vehicle Interior Section: Supplemental Restraint Systems
Model Year: 2008 Model: LX570 Doc ID: RM0000010VM02XX
Title: SUPPLEMENTAL RESTRAINT SYSTEMS: OCCUPANT CLASSIFICATION SYSTEM: DATA LIST / ACTIVE TEST (2008 LX570)

DATA LIST / ACTIVE TEST

1. DATA LIST

HINT:

Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

(a) Connect the Techstream to the DLC3.

(b) Turn the engine switch on (IG).

(c) Turn the Techstream on.

(d) Enter the following menus: Body Electrical / Occupant Detection / Data List.

(e) According to the display on the Techstream, read the "Data List".

Occupant Detection

Tester Display

Measurement Item/Range

Normal Condition

Diagnostic Note

Passenger Classification

Passenger classification / NG, AM50, AF05, Child or OFF

NG: Data not determined

AM50: Adult seated and seat in rear position

AF05: Adult seated and seat in front position

Child: Child seated

OFF: Vacant

-

Passenger Buckle SW

Buckle switch (passenger side) / Unset, Set or NG

Set: Passenger side seat belt fastened

Unset: Passenger side seat belt unfastened

NG: Data is not determined

-

Pressure sensor output

Pressure sensor output / Min.:0, Max.: 255

0 to 210

-

Filtered pressure sensor output

Filtered pressure sensor output / Min.: 0, Max.: 255

38 to 240

If the value is outside the range of Specified Condition for Zero Point Calibration, check whether any objects are placed on the seat cushion and that the seat cushion is fitted correctly.

Thermistor temperature output

Thermistor temperature output / Min.: -40°C (-40°F), Max.: 90°C (194°F)

-40 to 85°C

(-40 to 185°F)

If the value is outside the range of Specified Condition for Zero Point Calibration, adjust the temperature to the proper range by using the air conditioner, etc.

Weight threshold

Weight threshold / Min.: 0, Max.: 255

36 to 67

(reference value)

-

Filtered belt tension output

Filtered belt tension output / Min.: 0, Max.: 255

39 to 229

-

Empty threshold value from the seat factory

Empty threshold value from seat factory / Min.: 0, Max.: 255

38 to 75

-

Allow threshold

Threshold value for adult passenger or not from seat factory / Min.: 0, Max.: 255

43 to 64

(reference value)

-

Number of Present DTC

Number of stored trouble codes / Min.: 0, Max.: 255

0

-

Number of Past DTC

Number of past trouble codes / Min.: 0, Max.: 255

0

-