Room Temperature Sensor
|
Front room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
|
Actual room temperature for front seat displayed
|
Open in the circuit: -19°C (-2.2°F).
Short in the circuit: 70°C (158°F).
|
|
Ambient Temp Sensor
|
Ambient temperature sensor /
Min.: -23.3°C (-9.94°F)
Max.: 65.95°C (150.71°F)
|
Actual ambient temperature displayed
|
Open in the circuit: -53°C (-63.4°F).
Short in the circuit: 126°C (258.8°F).
|
|
Adjusted Ambient Temp
|
Adjusted ambient temperature /
Min.: -30.8°C (-23.44°F)
Max.: 50.8°C (123.44°F)
|
Adjusted ambient temperature displayed
|
-
|
|
Evaporator Fin Thermistor
|
No. 1 cooler thermistor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
|
Actual evaporator temperature displayed
|
Open in the circuit: -73°C (-99.4°F).
Short in the circuit: 114°C (237.2°F).
|
|
Evaporator Target Temp
|
Target evaporator temperature /
Min.: 1.5°C (34.7°F)
Max.: 4.0°C (39.2°F)
|
Target evaporator temperature displayed
|
-
|
|
Solar Sensor (D Side)
|
Driver side solar sensor /
Min.: 0, Max.: 255
|
Driver side solar sensor voltage increases as brightness increases
|
Open in the circuit: 0.
Short in the circuit: 255.
|
|
Solar Sensor (P Side)
|
Passenger side solar sensor /
Min.: 0, Max.: 255
|
Passenger side solar sensor voltage increases as brightness increases
|
Open in the circuit: 0.
Short in the circuit: 255.
|
|
Engine Coolant Temp
|
Engine coolant temperature /
Min.: 1.3°C (34.34°F)
Max.: 90.55°C (194.99°F)
|
Actual engine coolant temperature displayed while engine warmed up
|
-
|
|
Set Temperature (D Side)
|
Driver side set temperature /
Lo: 17.5°C (63.5°F)
Hi: 32.5°C (90.5°F)
|
Driver side actual set temperature displayed
|
-
|
|
Set Temperature (P Side)
|
Passenger side set temperature /
Lo: 17.5°C (63.5°F)
Hi: 32.5°C (90.5°F)
|
Passenger side actual set temperature displayed
|
-
|
|
Hand Free Telephone
|
Handsfree telephone / OFF or ON
|
ON: Handsfree telephone used
OFF: Handsfree telephone not used
|
-
|
|
Blower Motor Speed Level
|
Blower motor speed level /
Min.: 0
Max.: 31
|
Increases in range between 0 and 31 as blower motor speed increases
|
-
|
|
Emission Gas Nox Sensor
|
Smog ventilation sensor/
Min.: 0, Max.: 255
|
Increases as gas amount increases
|
-
|
|
Emission Gas Sensor
|
Smog ventilation sensor /
Min.: 0, Max.: 255
|
Decreases as gas amount increases
|
-
|
|
Regulator Pressure Sensor
|
Refrigerant pressure sensor /
Min.: -0.4566 MPaG
Max.: 3.2943 MPaG
|
Actual refrigerant pressure displayed
|
-
|
|
Room Temp Sensor (Rear)
|
Rear room temperature sensor LH /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
|
Actual rear room temperature for LH seat displayed
|
Open in the circuit: -19°C (-2.2°F).
Short in the circuit: 70°C (158°F).
|
|
Ambient Temp Sens (Rear)
|
Rear evaporator temperature sensor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
|
Actual rear evaporator temperature displayed
|
Open in the circuit: -73°C (-99.4°F).
Short in the circuit: 114°C (237.2°F).
|
|
Blower Motor Level (Rear)
|
Rear blower motor speed level /
Min.: 0, Max.: 31
|
Increases in range between 0 to 31 as rear blower motor speed increases
|
-
|
|
Air Outlet Servo Pulse (R)
|
Rear air outlet damper servo motor target pulse/
Min.: 7, Max.: 83
|
FOOT: 7 (pulse)
B/L: 42 (pulse)
FACE: 83 (pulse)
|
-
|
|
Air Mix Servo Targ Pulse(D)
|
Air mix damper servo motor (for driver side) target pulse /
Min.: 8, Max.: 90
|
Max cool: 90 (pulse)
Max hot: 8 (pulse)
|
-
|
|
Air Mix Servo Targ Pulse(P)
|
Air mix damper servo motor (for front passenger side) target pulse /
Min.: 8, Max.: 90
|
Max cool: 8 (pulse)
Max hot: 90 (pulse)
|
-
|
|
Air Inlet Damper Targ Pulse
|
REC/FRS damper servo motor target pulse /
Min.: 9, Max.: 37
|
RECIRCULATION: 37 (pulse)
FRESH: 9 (pulse)
|
-
|
|
Cool Air Bypass Pulse
|
Cool air bypass damper servo motor target pulse /
Min.: 6, Max.: 57
|
Shut: 6 (pulse)
Open: 57 (pulse)
|
-
|
|
Electric Heater Count
|
Number of electric heaters operating /
Min.: 0, Max.: 3
|
-
|
-
|
|
Shift Set Temperature
|
Set temperature / +2 C, +1 C, NORMAL, -1 C or -2 C
|
Customized value displayed
|
-
|
|
Air Inlet Mode
|
Air inlet mode / AUTO or MANUAL
|
Customized value displayed
|
-
|
|
Compressor Mode
|
Compressor mode / AUTO or MANUAL
|
Customized value displayed
|
-
|
|
Compressor/DEF Mode
|
Compressor/DEF mode / LINK or NORMAL
|
Customized value displayed
|
-
|
|
Evaporator Control
|
Evaporator control / AUTO or MANUAL
|
Customized value displayed
|
-
|
|
Emission Gas Sensor Shift
|
Emission gas sensor shift / MU MORE, MORE, LI MORE, NORMAL, LI LESS, LESS or MU LESS
|
Customized value displayed
|
-
|
|
Button Press Buzzer
|
Button press buzzer / ON or OFF
|
Customized value displayed
|
-
|
|
Ambient Temperature Shift
|
Ambient temperature shift / +3 C, +2 C, +1 C, NORMAL, -1 C, -2 C or -3 C
|
Customized value displayed
|
-
|
|
A/O Damper FACE Pos(D)
|
Air outlet damper servo motor (for driver side mode) target pulse /
Min.: 6, Max.: 117
|
FACE: 109 (pulse)
FACE2: 109 (pulse)
FACE3: 117 (pulse)
B/L1: 93 (pulse)
B/L2: 81 (pulse)
FOOT-D: 52 (pulse)
FOOT-R: 41 (pulse)
FOOT: 41 (pulse)
F/D: 18 (pulse)
DEF: 6 (pulse)
|
-
|
|
A/O Damper FACE Pos(P)
|
Air outlet damper servo motor (for front passenger side mode) target pulse /
Min.: 6, Max.: 117
|
FACE1: 117 (pulse)
FACE2: 109 (pulse)
B/L1: 93 (pulse)
B/L2: 81 (pulse)
FOOT-F: 41 (pulse)
FOOT-R: 41 (pulse)
FOOT-D: 52 (pulse)
F/D: 18 (pulse)
DEF: 6 (pulse)
|
-
|
|
Air Mix Servo Targ Pls(F&R D)
|
Front air mix damper servo motor (for driver side rear air flow) target pulse /
Min.: 13, Max.: 41
|
Max cool: 13 (pulse)
Max hot: 41 (pulse)
|
-
|
|
Air Mix Servo Targ Pls(F&R P)
|
Front air mix damper servo motor (for front passenger side rear air flow) target pulse /
Min.: 5, Max.: 33
|
Max cool: 33 (pulse)
Max hot: 5 (pulse)
|
-
|
|
Air Outlet Servo Pls (F&R D)
|
Air outlet damper servo motor (for rear seat mode) target pulse /
Min.: 9, Max.: 79
|
FACE1: 9 (pulse)
FACE2: 9 (pulse)
B/L1: 28 (pulse)
B/L2: 34 (pulse)
FOOT-O: 41 (pulse)
FOOT-D: 41 (pulse)
FOOT-R: 41 (pulse)
FOOT-F: 58 (pulse)
F/D: 67 (pulse)
DEF: 79 (pulse)
|
-
|
|
Room Temperature Sensor (RP)
|
Rear room temperature sensor RH /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
|
Actual rear room temperature for RH seat displayed
|
Open in the circuit: -19°C (-2.2°F).
Short in the circuit: 70°C (158°F).
|
|
Set Temperature (Rear D side)
|
Rear driver side set temperature /
Lo: 17.5°C (63.5°F)
Hi: 32.5°C (90.5°F)
|
Rear driver side actual set temperature displayed
|
-
|
|
Set Temperature (Rear P side)
|
Rear passenger side set temperature /
Lo: 17.5°C (63.5°F)
Hi: 32.5°C (90.5°F)
|
Rear passenger side actual set temperature displayed
|
-
|
|
Pls Servo Test Sts
|
Pulse servo motor test status / 00, 01, 02, 03 or 04
|
Not in effect: 00
During test: 01
Completed without malfunction: 02
Completed with malfunction: 03
Interrupted: 04
|
-
|
|
A/M Servo Targ Pulse (Rear D)
|
Rear air mix damper servo motor LH target pulse /
Min.: 9
Max.: 54
|
Max cool: 9 (pulse)
Max hot: 54 (pulse)
|
-
|
|
A/M Servo Targ Pulse (Rear P)
|
Rear air mix damper servo motor RH target pulse /
Min.: 8
Max.: 53
|
Max cool: 53 (pulse)
Max hot: 8 (pulse)
|
-
|
|
Foot Duct Sensor (Rear D)
|
DUCT SENSOR /
Min.: -12.7°C (9.14°F)
Max.: 76.55°C (169.79°F)
|
Actual temperature measured by duct sensor LH displayed
|
Open in the circuit: -30°C (86°F).
Short in the circuit: 80.6°C (177°F).
|
|
Foot Duct Sensor (Rear P)
|
DUCT SENSOR /
Min.: -12.7°C (9.14°F)
Max.: 76.55°C (169.79°F)
|
Actual temperature measured by duct sensor RH displayed
|
Open in the circuit: -30°C (86°F).
Short in the circuit: 80.6°C (177°F).
|
|
Number of Trouble Codes
|
Number of trouble codes /
Min.: 0, Max.: 255
|
Number of DTCs displayed
|
-
|