Last Modified: 11-27-2007 |
1.6 A |
|
Service Category: Engine/Hybrid System |
Section: Engine Control |
|
Model Year: 2008 |
Model: LX570 |
Doc ID: RM000003291007X |
|
Title: 3UR-FE ENGINE CONTROL: ECM: INSTALLATION (2008 LX570) |
INSTALLATION
1. INSTALL GASKET
(a) Clean the ECM seal surface with non-residue solvent.
(b) Attach a new gasket to the ECM.
2. INSTALL ECM
|
(a) Install the ECM with the 4 bolts.
Torque: 8.0 N·m (82 kgf·cm, 71 in·lbf)
NOTICE:
-
Make sure the gasket is not folded or caught on any area of the surrounding part.
-
Make sure there is no foreign matter caught between the gasket and surrounding part.
-
Do not damage the gasket.
|
|
(b) Connect the 2 ECM connectors and push each lock lever down to lock the ECM connectors.
NOTICE:
-
Make sure that the lock levers are raised 90° before connecting the ECM connectors. Failure to do this may cause the lock lever and terminals to break.
-
Do not twist the wire harness when connecting the ECM connectors.
|
3. INSTALL CONNECTOR HOLDER BLOCK
|
(a) Install the connector holder block with the 3 bolts.
Torque: 8.0 N·m (82 kgf·cm, 71 in·lbf)
|
4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected
.
5. INSTALL ENGINE ROOM SIDE COVER RH
6. INSTALL ENGINE ROOM SIDE COVER LH
|