(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Damping Mode Select Switch
|
Tester Connection
|
Switch Condition
|
Specified Condition
|
|
3 (ECU1) - 6 (E)
|
SPORT
|
Below 1 Ω
|
|
Except SPORT
|
10 kΩ or higher
|
|
5 (ECU2) - 6 (E)
|
COMF
|
Below 1 Ω
|
|
Except COMF
|
10 kΩ or higher
|
Height Control Switch
|
Tester Connection
|
Switch Condition
|
Specified Condition
|
|
12 (LO) - 6 (E)
|
Down button of height control switch is pushed.
|
Below 1 Ω
|
|
Height control switch is not pushed or up button is pushed.
|
10 kΩ or higher
|
|
8 (HI) - 6 (E)
|
Up button of height control switch is pushed.
|
Below 1 Ω
|
|
Height control switch is not pushed or down button is pushed.
|
10 kΩ or higher
|
Height Control OFF Switch
|
Tester Connection
|
Switch Condition
|
Specified Condition
|
|
4 (N) - 6 (E)
|
Height control OFF switch is pushed.
|
Below 1 Ω
|
|
Height control OFF switch is not pushed.
|
10 kΩ or higher
|
If the result is not as specified, replace the integration control and panel assembly.
|