SERVICE DATA

Voltage Inverter (Standard Voltage)

Connector Condition

Tester Connection

Switch Condition

Specified Condition

Component without harness connected

K16-1 (IG) - K16-4 (GND)

Engine switch on (IG)

10 to 16 V

GND (K16-4) - Body ground

K16-4 (GND) - Body ground

Always

Below 1 V

Voltage Inverter (Standard Voltage)

Connector Condition

Tester Connection

Switch Condition

Specified Condition

Component with harness connected

K16-3 (AC1) - K16-7 (AC2)

Engine switch on (IG)

Main switch on

AC115V