THERMOSTAT > INSPECTION |
| 1. INSPECT THERMOSTAT |
![]() |
![]() |
Immerse the thermostat in water and gradually heat the water.
Check the valve opening temperature of the thermostat.
![]() |
Check the valve lift.
Check that the valve is fully closed when the thermostat temperature is low (below 77°C (171°F)).