SHIFT LEVER POSITION SENSOR > INSPECTION

for Preparation Click here



1. INSPECT PARK/NEUTRAL POSITION SWITCH


    G029274E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:


    A-1 (D)
    A-2 (N)
    A-3 (P)
    A-4 (R)
    A-5 (MJ)
    A-6 (FD)
    A-7 (B)
    A-9 (RV)
    P position
    10 kΩ or higher
    4.2 to 5.1 kΩ
    Below 1 Ω
    10 kΩ or higher
    Below 1 Ω
    10 kΩ or higher
    10 kΩ or higher
    10 kΩ or higher
    R position
    10 kΩ or higher
    4.2 to 5.1 kΩ
    10 kΩ or higher
    Below 1 Ω
    Below 1 Ω
    10 kΩ or higher
    10 kΩ or higher
    Below 1 Ω
    N position
    10 kΩ or higher
    Below 1 Ω
    10 kΩ or higher
    10 kΩ or higher
    Below 1 Ω
    10 kΩ or higher
    10 kΩ or higher
    10 kΩ or higher
    D position
    Below 1 Ω
    4.2 to 5.1 kΩ
    10 kΩ or higher
    10 kΩ or higher
    Below 1 Ω
    Below 1 Ω

    10 kΩ or higher
    B position
    10 kΩ or higher
    4.2 to 5.1 kΩ
    10 kΩ or higher
    10 kΩ or higher
    Below 1 Ω
    Below 1 Ω
    Below 1 Ω
    10 kΩ or higher