DTC P0A1A-200 Generator Control Module |
DTC P0A1A-792 Generator Control Module |
DTC P0A1A-793 Generator Control Module |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A1A | 200 | R/D resolver angle error |
|
| ↑ | 792 | REF frequency error |
|
| ↑ | 793 | REF signal transmission stop error |
|

| 1.READ OUTPUT DTC (HV) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position.
Select the following menu items: Powertrain / Hybrid Control / DTC.
Read output DTC. (Click here)
| DTC No. | Relevant Diagnosis |
| P0A4B-253, P0A4C-513, P0A4D-255 | Generator resolver circuit |
|
| ||||
| NO | |
| 2.CHECK HARNESS AND CONNECTOR (MG ECU - GENERATOR RESOLVER) |
Turn the ignition switch off and remove the service plug grip. (Click here)
Remove the inverter cover. (Click here)
![]() |
Disconnect the I24 connector from the MG ECU.
Measure the voltage according to the value(s) in the table below when the ignition switch is in the ON position.
| Tester Connection | Specified Condition |
| GRF (I24-12) - Body ground | Below 1 V |
| GRFG (I24-22) - Body ground | Below 1 V |
| GSN (I24-11) - Body ground | Below 1 V |
| GSNG (I24-10) - Body ground | Below 1 V |
| GSC (I24-9) - Body ground | Below 1 V |
| GRF (I24-8) - Body ground | Below 1 V |
Turn the ignition switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| GSF (I24-12) - GRFG (I24-22) | 7.65 to 10.2 Ω |
| GSN (I24-11) - GSNG (I24-10) | 12.6 to 16.8 Ω |
| GCS (I24-9) - GCSG (I24-8) | 12.6 to 16.8 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| GSF (I24-12) or GRFG (I24-22) - Body ground | 10 kΩ or higher |
| GSN (I24-11) or GSNG (I24-10) - Body ground | 10 kΩ or higher |
| GCS (I24-9) or GCSG (I24-8) - Body ground | 10 kΩ or higher |
|
| ||||
| NG | |
| 3.INSPECT GENERATOR RESOLVER |
![]() |
Remove the w/ converter inverter. (Click here)
Disconnect the M6 generator resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| GRF (M6-1) - GRFG (M6-6) | 7.65-10.2 Ω |
| GSN (M6-2) - GSNG ((M6-7) | 12.6-16.8 Ω |
| GCS (M6-3) - GCSG (M6-8) | 12.6-16.8 Ω |
Using a megohmmeter, measure the insulation resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| GRF (M6-1) - GSN (M6-2) | 10 MΩ or higher |
| GRF (M6-1) - GCS (M6-3) | 10 MΩ or higher |
| GSN (M6-2) - GCS (M6-3) | 10 MΩ or higher |
| GRFG (M6-6) - GSNG (M6-7) | 10 MΩ or higher |
| GRFG (M6-6) - GCSG (M6-8) | 10 MΩ or higher |
| GSNG (M6-7) - GCSG (M6-8) | 10 MΩ or higher |
| Each terminal listed above - Transaxle housing | 10 MΩ or higher |
|
| ||||
| OK | ||
| ||