DTC B1462/62 Room Humidity Sensor Circuit |
| DTC No. | DTC Detecting Condition | Trouble Area |
| B1462/62 | Open or short in room humidity sensor circuit |
|

| 1.READ VALUE OF INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch ON and push the intelligent tester main switch on.
Select the item below in the DATA LIST, and read the display on the intelligent tester.
| Item | Measurement Item/Display (Range) | Normal Condition | Diagnostic Note |
| HUMIDITY SENS | Humidity sensor / min.: 0% max.: 100% | Actual cabin humidity is displayed | - |
| Result | Proceed to |
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY |
![]() |
Remove the A/C amplifier assembly with the connectors still connected.
Measure the voltage according to the value(s) in the table below.
| Tester connection (Symbols) | Condition | Specified condition |
| A11-22 (RH) - A11-24 (SSR+) | Ignition switch ON at 25°C (77°F) | 1.8 to 2.2 V |
| A11-22 (RH) - A11-24 (SSR+) | Ignition switch ON at 40°C (104°F) | 1.2 to 1.6 V |
| Result | Proceed to |
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 3.INSPECT A/C ROOM TEMPERATURE SENSOR |
![]() |
Remove the A/C room temperature sensor.
Turn the ignition switch ON.
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester connection (Symbols) | Condition | Specified condition |
| A33-3 (S5) - A33-4 (VO) | at 25°C (77°F) Humidity 10% | 0.7 to 1.08 V |
| A33-3 (S5) - A33-4 (VO) | at 25°C (77°F) Humidity 20% | 0.72 to 1.57 V |
| A33-3 (S5) - A33-4 (VO) | at 25°C (77°F) Humidity 30% | 1.13 to 1.95 V |
| A33-3 (S5) - A33-4 (VO) | at 25°C (77°F) Humidity 40% | 1.61 to 2.24 V |
| A33-3 (S5) - A33-4 (VO) | at 25°C (77°F) Humidity 50% | 1.99 to 2.46 V |
| A33-3 (S5) - A33-4 (VO) | at 25°C (77°F) Humidity 60% | 2.26 to 2.66 V |
| A33-3 (S5) - A33-4 (VO) | at 25°C (77°F) Humidity 70% | 2.48 to 2.85 V |
| A33-3 (S5) - A33-4 (VO) | at 25°C (77°F) Humidity 80% | 2.68 to 3.04 V |
| A33-3 (S5) - A33-4 (VO) | at 25°C (77°F) Humidity 90% | 2.87 to 3.05 V |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (A/C ROOM TEMPERATURE SENSOR - A/C AMPLIFIER ASSEMBLY) |
![]() |
Disconnect the connector from the A/C amplifier assembly.
Measure the resistance according to the value(s) in the table below.
| Tester connection (Symbols) | Condition | Specified condition |
| A11-24 (SSR+) - A33-3 (S5) | Always | Below 1 Ω |
| A11-22 (RH) - A33-4 (VO) | Always | Below 1 Ω |
| A11-3 (SSR+) - Body ground | Always | 10 kΩ or higher |
| A11-22 (RH) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||