DTC P0A7A-344 Generator Inverter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| PA7A | 344 | Malfunction in monitoring generator torque performance |
|
| 1.READ OUTPUT DTC (HV) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position.
Select the following menu items: Powertrain / Hybrid Control / DTC.
Read output DTCs. (Click here)
| DTC No. | Relevant Diagnosis |
| P0A1A (all details), P0A1B (all details), P0A1C (all details) | MG ECU circuit malfunction |
| P0A1D (all details) | HV ECU circuit malfunction |
| P0A3F-243, P0A40-500, P0A41-245 | Motor resolver circuit |
| P0A45-669, P0A46-671, P0A47-670 | Rear motor resolver circuit |
| P0A4B-253, P0A4C-513, P0A4D-255 | Generator resolver circuit |
| P0A51-174, P0A55-687 | MG ECU circuit malfunction |
| P0A60 (all details), P0A63 (all details) | Motor current sensor circuit |
| P0A69 (all details), P0A6C (all details) | Rear motor current sensor circuit |
| P0A72 (all details), P0A75 (all details) | Generator current sensor circuit |
| P0A78-510, 508, 586, 266, 272, 280, 304, 267, 278, 283, 285, 305, 523 | Motor inverter function malfunction |
| P0A79-703, 701, 672, 690, 691, 697, 698 | Rear motor inverter function malfunction |
| P0A7A-522, 520, 309, 321, 323, 342, 343 | Generator inverter function malfunction |
| P0A94-585, 587, 561, 551, 588, 589, 545, 546, 552, 558, 559, 583, 584, 590 | Boost converter circuit |
| P0AA6 (all details), P3004-132 | High-voltage system |
| P3232-749, P3233-750 | HV gate shutdown wiring malfunction |
|
| ||||
| NO | |
| 2.CHECK CONNECTION CONDITION OF MG ECU CONNECTOR (LOOSENESS AND POOR CONTACT) |
Turn the ignition switch off and remove the service plug grip. (Click here)
Remove the inverter cover. (Click here)
![]() |
Check the connections of the MG ECU connectors.
|
| ||||
| OK | |
| 3.CHECK W/ CONVERTER INVERTER ASSEMBLY (GENERATOR) |
![]() |
Check that the service plug grip is removed.
Check that the bolts for the three-phase AC cable for Generator are tightened to the specified torque.
|
| ||||
| OK | |
| 4.INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR) |
Check that the service plug grip is removed.
![]() |
Disconnect the three-phase AC cables for Motor and Generator from the w/ converter inverter assembly.
![]() |
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| U - V | 48 to 59 mΩ (20°C) |
| V - W | 48 to 59 mΩ (20°C) |
| W - U | 48 to 59 mΩ (20°C) |
To correct the resistance varying depending on the temperature, use the following formula to calculate the resistance at 20°C.
Calculate the difference between the maximum and minimum resistance.
Using a megohmmeter, measure the insulation resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| U - Body ground and shielded wire ground | 10 MΩ or higher |
| V - Body ground and shielded wire ground | 10 MΩ or higher |
| W - Body ground and shielded wire ground | 10 MΩ or higher |
|
| ||||
| OK | ||
| ||