DTC    P0A94-556    DC / DC Converter Performance

for Preparation Click here


DESCRIPTION

Refer to the description of the boost converter. (Click here)

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A94
556
Boost converter inverter fail signal detection (overcurrent by HV transaxle assembly malfunction)
  1. Wire harness or connector
  2. Hybrid vehicle transaxle assembly
  3. Rear traction motor w/ transaxle assembly

MONITOR DESCRIPTION

If over-amperage flows through the boost converter due to an internal short, the boost converter transmits a boost converter fail signal to the MG ECU. Upon receiving this signal, the HV control ECU illuminates the MIL and sets a DTC.

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals.

HINT:
At least 5 minutes is required to discharge the high-voltage capacitor inside the w/ converter inverter assembly.

1.READ OUTPUT DTC (HV)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to the ON position.

  1. Select the following menu items: Powertrain / Hybrid Control / DTC.

  1. Read output DTC. (Click here)

    Result:
    The DTCs shown in the table below are output:

    DTC No.
    Relevant Diagnosis
    P0A1D
    HV control ECU malfunction
    P0A2B, P0A2C, P0A2D
    Motor temperature sensor circuit
    P0A37, P0A38, P0A39
    Generator temperature sensor circuit
    P0A3F, P0A40, P0A41
    Motor resolver circuit
    P0A4B, P0A4C, P0A4D
    Generator resolver circuit
    P0A60, P0A63
    Motor current sensor circuit
    P0A72, P0A75
    Generator current sensor circuit
    P0A78
    Motor inverter function malfunction
    P0A7A
    Generator inverter function malfunction
    P0A90
    Motor function malfunction
    P0A92
    Generator function malfunction
    P0A94 (Except for 556)
    Boost converter function malfunction
    P0AA1, P0AA2, P0AA4, P0AA5
    System main relay circuit
    P0AA6, P3004
    High-voltage system
    P0A79
    Rear motor inverter function malfunction
    P0A45, P0A46, P0A47
    Rear motor resolver malfunction
    P0A69, P0A6C, P0A55
    Rear motor current sensor malfunction

    HINT:
    1. Turning the ignition switch to the ON position with the service plug grip and inverter cover removed causes interlock switch system DTC P0A0D-350 to be output.
    2. P0A78-284 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.



YES
GO TO DTC CHART
NO


2.CHECK CONNECTION CONDITION OF MG ECU CONNECTOR (LOOSENESS AND POOR CONTACT)

CAUTION:
Be sure to wear insulated gloves.

  1. Turn the ignition switch off and remove the service plug grip. (Click here)

    NOTICE:
    Do not put the vehicle into the READY-on state with the service plug grip removed as this may cause a malfunction.

  1. Remove the inverter cover. (Click here)

    NOTICE:
    1. Wrap the interlock round terminal for the inverter cover with vinyl tape to prevent it from shorting to ground.
    2. Prevent water in the reservoir tank from entering the inverter.
    3. Removing the inverter cover causes the MG ECU board to be exposed. Therefore, temporarily install the inverter cover for each area to be inspected.



    A103665E03
  1. Check the connections of the MG ECU connectors.

    OK:
    Connectors are connected securely and there is no poor connection.



NG
CONNECT SECURELY
OK


3.CONFIRM INFORMATION (EXCLUSIVE INFO 4)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to the ON position.

  1. Select the following menu items: Powertrain / Hybrid Control / DTC.

  1. Read output DTC.

    HINT:
    Turning the ignition switch to the ON position with the service plug grip and inverter cover removed causes interlock switch system DTC P0A0D-350 to be output.

  1. Display freeze frame data corresponding to DTC P0A94 and select the information.

  1. Select INF code 556 and read "Exclusive Info 4".

    Result:
    Displayed item in exclusive information 4
    Proceed to
    -63 to 64
    A
    65 to 128
    B



B
Go to step 6
A


4.CHECK HARNESS AND CONNECTOR (MG ECU - MOTOR RESOLVER)


    A103666E04
  1. Disconnect the I24 connector from the MG ECU.

  1. Measure the voltage according to the value(s) in the table below when the ignition switch is in the ON position.

    Standard Voltage:
    Tester Connection
    Specified Condition
    MRF (I24-13) - Body ground
    Below 1 V
    MRFG (I24-23) - Body ground
    Below 1 V
    MSN (I24-21) - Body ground
    Below 1 V
    MSNG (I24-20) - Body ground
    Below 1 V
    MCS (I24-19) - Body ground
    Below 1V
    MCSG (I24-18) - Body ground
    Below 1 V

  1. Turn the ignition switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Specified Condition
    MRF (I24-13) - MRFG (I24-23)
    7.65 to 10.2 Ω
    MSN (I24-21) - MSNG (I24-20)
    12.6 to 16.8 Ω
    MCS (I24-19) - MCSG (I24-18)
    12.6 to 16.8 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Specified Condition
    MRF (I24-13) or MRFG (I24-23) - Body ground
    10 kΩ or higher
    MSN (I24-21) or MSNG (I24-20) - Body ground
    10 kΩ or higher
    MCS (I24-19) or MCSG (I24-18) - Body ground
    10 kΩ or higher



NG
Go to step 7
OK


5.CHECK HARNESS AND CONNECTOR (MG ECU - GENERATOR RESOLVER)


    A103666E03
  1. Disconnect the I24 connector from the MG ECU.

  1. Measure the voltage according to the value(s) in the table below when the ignition switch is in the ON position.

    Standard Voltage:
    Tester Connection
    Specified Condition
    GRF (I24-12) - Body ground
    Below 1 V
    GRFG (I24-22) - Body ground
    Below 1 V
    GSN (I24-11) - Body ground
    Below 1 V
    GSNG (I24-10) - Body ground
    Below 1 V
    GCS (I24-9) - Body ground
    Below 1 V
    GCSG (I24-8) - Body ground
    Below 1 V

  1. Turn the ignition switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Specified Condition
    GRF (I24-12) - GRFG (I24-22)
    7.65 to 10.2 Ω
    GSN (I24-11) - GSNG (I24-10)
    12.6 to 16.8 Ω
    GCS (I24-9) - GCSG (I24-8)
    12.6 to 16.8 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Specified Condition
    GRF (I24-12) or GRFG (I24-22) - Body ground
    10 kΩ or higher
    GSN (I24-11) or GSNG (I24-10) - Body ground
    10 kΩ or higher
    GCS (I24-9) or GCSG (I24-8) - Body ground
    10 kΩ or higher



NG
Go to step 9
OK

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY 

6.CHECK HARNESS AND CONNECTOR (MG ECU - REAR MOTOR RESOLVER)


    A103667E04
  1. Disconnect the I25 connector from the MG ECU.

  1. Measure the voltage according to the value(s) in the table below when the ignition switch is in the ON position.

    Standard Voltage:
    Tester Connection
    Specified Condition
    RRF (I25-21) - Body ground
    Below 1 V
    RRFG (I25-22) - Body ground
    Below 1 V
    RSN (I25-29) - Body ground
    Below 1 V
    RSNG (I25-30) - Body ground
    Below 1 V
    RCS (I25-11) - Body ground
    Below 1 V
    RCSG (I25-23) - Body ground
    Below 1 V

  1. Turn the ignition switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Specified Condition
    RRF (I25-21) - RRFG (I25-22)
    7.65 to 10.2 Ω
    RSN (I25-29) - RSNG (I25-30)
    12.6 to 16.8 Ω
    RCS (I25-11) - RCSG (I25-23)
    12.6 to 16.8 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Specified Condition
    RRF (I25-21) or RRFG (I25-22) - Body ground
    10 kΩ or higher
    RSN (I25-29) or RSNG (I25-30) - Body ground
    10 kΩ or higher
    RCS (I25-11) or RCSG (I25-23) - Body ground
    10 kΩ or higher



NG
Go to step 11
OK

REPLACE REAR TRACTION MOTOR W/TRANSAXLE ASSEMBLY 

7.CHECK CONNECTION CONDITION OF MOTOR RESOLVER CONNECTOR (LOOSENESS AND POOR CONTACT)


    A105165
  1. Check the connections of the motor resolver connector.

    OK:
    Connectors are connected securely and there is no poor connection.



NG
CONNECT SECURELY
OK


8.INSPECT MOTOR RESOLVER


    A083675E04
  1. Disconnect the M7 motor resolver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Specified Condition
    MRF (M7-1) - MRFG (M7-4)
    7.65 to 10.2 Ω
    MSN (M7-2) - MSNG (M7-5)
    12.6 to 16.8 Ω
    MCS (M7-3) - MCSG (M7-6)
    12.6 to 16.8 Ω

  1. Using a megohmmeter, measure the insulation resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Specified Condition
    MRF (M7-1) - MSN (M7-2)
    10 MΩ or higher
    MRF (M7-1) - MCS (M7-3)
    10 MΩ or higher
    MSN (M7-2) - MCS (M7-3)
    10 MΩ or higher
    MRFG (M7-4) - MSNG (M7-5)
    10 MΩ or higher
    MRFG (M7-4) - MCSG(M7-6)
    10 MΩ or higher
    MSNG (M7-5) - MCSG (M7-6)
    10 MΩ or higher
    Each terminal listed above - Transaxle housing
    10 MΩ or higher



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR 

9.CHECK CONNECTION CONDITION OF GENERATOR RESOLVER CONNECTOR (LOOSENESS AND POOR CONTACT)
  1. Remove the w/ converter inverter assembly.



    A105167
  1. Check the connections of the generator resolver connector.

    OK:
    Connectors are connected securely and there is no poor connection.



NG
CONNECT SECURELY
OK


10.INSPECT GENERATOR RESOLVER


    A105163E02
  1. Disconnect the M6 generator resolver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Specified Condition
    GRF (M6-1) - GRFG (M6-6)
    7.65 to 10.2 Ω
    GSN (M6-2) - GSNG (M6-7)
    12.6 to 16.8 Ω
    GCS (M6-3) - GCSG (M6-8)
    12.6 to 16.8 Ω

  1. Using a megohmmeter, measure the insulation resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Specified Condition
    GRF (M6-1) - GSN (M6-2)
    10 MΩ or higher
    GRF (M6-1) - GCS (M6-3)
    10 MΩ or higher
    GSN (M6-2) - GCS (M6-3)
    10 MΩ or higher
    GRFG (M6-6) - GSNG (M6-7)
    10 MΩ or higher
    GRFG (M6-6) - GCSG (M6-8)
    10 MΩ or higher
    GSNG (M6-7) - GCSG (M6-8)
    10 MΩ or higher
    Each terminal listed above - Transaxle housing
    10 MΩ or higher



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR 

11.CHECK CONNECTION CONDITION OF REAR MOTOR RESOLVER CONNECTOR (LOOSENESS AND POOR CONTACT)


    A105166
  1. Check the connections of the rear motor resolver connector.

    OK:
    Connectors are connected securely and there is no poor connection.



NG
CONNECT SECURELY
OK


12.INSPECT REAR MOTOR RESOLVER
  1. Remove the w/ converter inverter assembly.



    A083675E05
  1. Disconnect the M11 rear motor resolver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Specified Condition
    RRF (M11-1) - RRFG (M11-4)
    7.65 to 10.2 Ω
    RSN (M11-2) - RSNG (M11-5)
    12.6 to 16.8 Ω
    RCS (M11-3) - RCSG (M11-6)
    12.6 to 16.8 Ω

  1. Using a megohmmeter, measure the insulation resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Specified Condition
    RRF (M11-1) - RSN (M11-2)
    10 MΩ or higher
    RRF (M11-1) - RCS (M11-3)
    10 MΩ or higher
    RSN (M11-2) - RCS (M11-3)
    10 MΩ or higher
    RRFG (M11-4) - RSNG (M11-5)
    10 MΩ or higher
    RRFG (M11-4) - RCSG (M11-6)
    10 MΩ or higher
    RSNG (M11-5) - RCSG (M11-6)
    10 MΩ or higher
    Each terminal listed above - Transaxle housing
    10 MΩ or higher



NG
REPLACE REAR TRACTION MOTOR W/TRANSAXLE ASSEMBLY
OK