LIGHTING SYSTEM > Automatic Light Control Sensor Circuit |

| 1.READ VALUE OF INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position and press the intelligent tester main switch ON.
Select the items below in the DATA LIST, and read the displays on the intelligent tester.
| Item | Measurement Item/ Display (Range) | Normal Condition | Diagnostic Note |
| Illumination Rate Info | Illumination rate/ON or OFF | ON: Illuminate rate ON OFF: Illuminate rate OFF | - |
|
| ||||
| OK | ||
| ||
| 2.CHECK HARNESS AND CONNECTOR (MULTIPLEX NETWORK BODY ECU - AUTOMATIC LIGHT CONTROL SENSOR) |
![]() |
Disconnect the automatic light control sensor connector and multiplex network body ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| CLTE (A13-3) - CLTE (B6-4) | Always | Below 1 Ω |
| CLTS (A13-5) - CLTS (B6-5) | Always | Below 1 Ω |
| CLTB (A13-6) - CLTB (B6-6) | Always | Below 1 Ω |
| CLTE (B6-4) - Body ground | Always | 10 kΩ or higher |
| CLTS (B6-5) - Body ground | Always | 10 kΩ or higher |
| CLTB (B6-6) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 3.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
Measure the voltage according to the value(s) in the table below.

| Tester connection | Condition | Specified voltage |
| CLTE (B6-4) - CLTB (B6-6) | Ignition switch OFF → ON | Below 1 V → 10 to 14 V |
|
| ||||
| OK | ||
| ||