POWER WINDOW CONTROL SYSTEM > PROBLEM SYMPTOMS TABLE

for Preparation Click here



POWER WINDOW CONTROL SYSTEM 
Symptom
Suspected area
See page
Power window does not operate with multiplex network master switch operation
1. ECU-B, ECU-IG, PWR fuse
-
2. Multiplex network master switch circuit (power source)
Click here
3. Power window regulator motor circuit
Click here
4. Multiplex network master switch
-
Power window does not operate with multiplex network switch operation (front passenger side)
1. PWR fuse
-
2. Multiplex network switch circuit (power source)
Click here
3. Power window regulator motor circuit (front passenger side)
Click here
4. Multiplex network switch (front passenger side)
-
Power window does not operate with multiplex network switch operation (rear LH side)
1. PWR fuse
-
2. Multiplex network switch circuit (power source)
Click here
3. Power window regulator motor circuit (rear LH side)
Click here
4. Multiplex network switch (rear LH side)
-
Power window does not operate with multiplex network switch operation (rear RH side)
1. PWR fuse
-
2. Multiplex network switch circuit (power source)
Click here
3. Power window regulator motor circuit (rear RH side)
Click here
4. Multiplex network switch (rear RH side)
-
AUTO UP/DOWN function does not operate on driver side
1. Diagnosis check
Click here
2. Power window regulator motor reset
Click here
3. Multiplex network master switch
-
4. Wire harness
-
AUTO UP/DOWN function does not operate on any door side except driver sides
1. Diagnosis check
Click here
2. Power window regulator motor reset
Click here
3. Multiplex network master switch
-
4. Wire harness
-
Remote UP/DOWN function does not operate
1. DATA LIST/ACTIVE TEST
Click here
2. Multiplex network master switch
Click here
3. Multiplex network body ECU
-
4. Wire harness
-
Power window can be operated after ignition switch is turned off even if operated conditions are not met
1. Front door courtesy switch
Click here
2. Wire harness
-
AUTO UP operation does not fully close power window (Jam protection function is activated)
1. Power window regulator motor reset
Click here
2. Check & Clean Glass run
-
3. Multiplex network master switch
-