METER / GAUGE SYSTEM > FAIL-SAFE CHART |
| Condition | Response | Recovery |
| Engine coolant temperature data is interrupted for 5 seconds. | The gauge needle indicates below "°C". | Engine coolant temperature data is received. |
| Condition | Response | Recovery |
| "P" to "D" data is interrupted for 3 seconds. | All indicator lights go off. | Normal data is received. |
| "B" data is interrupted for 3 seconds. | The "B" indicator light goes off. | Normal data is received. |
| Condition | Response | Recovery |
| ABS & brake data is interrupted for 3 seconds. | The warning light comes on. | Normal data is received. |
| Condition | Response | Recovery |
| Regular data is interrupted. | The data received most recently remains indicated. | Normal data is received. |
| Condition | Response | Recovery |
| P/S data is interrupted for 3 seconds.. | The indicator light comes on. | Normal data is received. |
| Condition | Response | Recovery |
| Regular data is interrupted. | The data received most recently remains indicated. | Normal data is received. |
| Condition | Response | Recovery |
| Regular data is interrupted. | The indicator light goes off. | Normal data is received. |
| Condition | Response | Recovery |
| Airbag data is interrupted for 10 seconds or there is a malfunction in the combination meter (meter CPU). | The warning light comes on. | Normal data is received. |
| Condition | Response | Recovery |
| The illumination data is interrupted for 10 seconds or abnormal data is received. | The display remains in daytime mode. | Normal data is received. |
| Condition | Response | Recovery |
| Cruise information data is interrupted for 60 seconds. | The display becomes blank (only measurement units displayed). | Normal data is received. |
| Energy flow data is interrupted for 2 seconds. | The energy flow display becomes blank. (Cursor does not appear.) | Normal data is received. |
| The battery data is interrupted for 2 seconds. | The display before receiving the data is displayed. | Normal data is received. |