CANISTER > INSPECTION |
| 1. INSPECT CHARCOAL CANISTER ASSEMBLY |
Check the appearance.
![]() |
Check for cracks or damage to the portions indicated by the arrows.
Replace the charcoal canister assembly when it is either damaged or cracks are found.
Check the ventilation.
![]() |
Check that there is ventilation in ports A and C when 4.90 kPa (50 gf/cm2, 0.71 psi) of air is applied to port B.
If there is no ventilation, replace the charcoal canister assembly.
![]() |
Plug ports A and C with your fingers.
Using a vacuum pump, apply 1.96 kPa (14.7 mmHg, 0.578 in.Hg) of vacuum to port B, then check there are no air leaks in ports A and C.
If there is air leaks, replace the charcoal canister assembly.
![]() |
Plug port B with your finger.
Check that there is ventilation in port C when 4.90 kPa (50 gf/cm2, 0.71 psi) of air is applied to port A.
If there is no ventilation, replace the charcoal canister assembly.