HEATED OXYGEN SENSOR > INSPECTION

for Preparation Click here



1. INSPECT OXYGEN SENSOR (for Bank 1)


    A082934E01
  1. Measure the resistance between terminals 1 (HT) and 2 (+B).

    Standard resistance:
    Condition
    Specified Condition
    20°C (68°F)
    11 to 16 Ω

    If the resistance is not as specified, replace the sensor.



2. INSPECT OXYGEN SENSOR (for Bank2)


    A080122E02
  1. Measure the resistance between terminals 1 (HT) and 2 (+B).

    Standard resistance:
    Condition
    Specified Condition
    20°C (68°F)
    11 to 16 Ω

    If the resistance is not as specified, replace the sensor.