MASS AIR FLOW METER > INSPECTION |
| 1. INSPECT MASS AIR FLOW METER |
Output voltage inspection.
Apply battery voltage across terminals 1 (+B) and 2 (E2G).
Connect the position (+) tester probe to terminal 3 (VG), and negative (-) tester probe to terminal 2 (E2G).
Blow air into the MAF meter, and check that the voltage fluctuates.
![]() |
Resistance inspection.
Using an ohmmeter, measure the resistance between terminals 4 (THA) and 5 (E2).
| Symbols (Terminal No.) | Resistance | Temperature |
| THA (4) - E2 (5) | 13.6 to 18.4 kΩ | -20° (-4°F) |
| THA (4) - E2 (5) | 2.21 to 2.69 kΩ | 20° (68°F) |
| THA (4) - E2 (5) | 0.49 to 0.67 kΩ | 60° (140°F) |