DOOR CONTROL SWITCH > INSPECTION

for Preparation Click here



1. INSPECT DOOR CONTROL SWITCH


    B066161E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    2 - 3
    Lock
    Below 1 Ω
    2 - 3
    1 - 2
    OFF (Free)
    10 kΩ or higher
    1 - 2
    Unlock
    Below 1 Ω

    HINT:
    If the result is not as specified, replace the switch.



    B066162E01
  1. Apply battery voltage to the door control switch and check that the switch illuminates.

    OK:
    Measurement Condition
    Specified Condition
    Battery positive (+) → Terminal 4
    Battery negative (-) → Terminal 2
    Illuminates

    HINT:
    If the result is not as specified, replace the switch.