CLOCK > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT INTEGRATION CONTROL & PANEL ASSEMBLY


    E110608E01
  1. Disconnect the C4 connector.

  1. Measure the voltage between the terminals according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    C4-1 (+B) -
    Body ground
    Always
    10 to 14 V
    C4-2 (ACC) -
    Body ground
    Turn the ignition switch to the off → ACC or ON position
    Below 1 V →
    10 to 14 V
    C4-9 (IG+) -
    Body ground
    Turn the ignition switch to the off → ACC or ON position
    Below 1 V →
    10 to 14 V

  1. Measure the resistance between the terminals according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    C4-7 (GND) -
    Body ground
    Always
    Below 1 Ω

    HINT:
    If the value is not as specified, replace the integration control & panel assembly.



2. INSPECT MULTI-DISPLAY


    E111223E01
  1. Disconnect the M5 connector.

  1. Measure the voltage between the terminals according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    M5-12 (+B) -
    Body ground
    Always
    10 to 14 V
    M5-11 (ACC) -
    Body ground
    Turn the ignition switch to the off → ACC or ON position
    Below 1 V →
    10 to 14 V
    M5-10 (IG) -
    Body ground
    Turn the ignition switch to the off → ACC or ON position
    Below 1 V →
    10 to 14 V

  1. Measure the resistance between the terminals according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    M5-3 (GND) -
    Body ground
    Always
    Below 1 Ω

    HINT:
    If the value is not as specified, replace the multi-display.