METER / GAUGE SYSTEM > Operating Light Control Rheostat does not Change Light Brightness |

| 1.READ VALUE OF INTELLIGENT TESTER |
Operate the intelligent tester according to the steps on the display and select "DATA LIST".
| Item | Measurement Item/Range (Display) | Normal Condition | Diagnostic Note |
| Light Control Rheostat | Light control rheostat / Min.: 0, Max.: 255 | Light control rheostat switch is Dark (0) → Bright (255) | - |
|
| ||||
| OK | ||
| ||
| 2.INSPECT LIGHT CONTROL RHEOSTAT |
![]() |
Remove the light control rheostat with connector still connected.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| R6-1 (E) - R6-7 (RV) | Rheostat knob is in the MAX. position | 8 to 12 kΩ |
| R6-1 (E) - R6-7 (RV) | Rheostat knob is in the MIN. position. | Approx. 0 Ω |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (BETWEEN COMBINATION METER AND LIGHT CONTROL RHEOSTAT) |
![]() |
Disconnect the C9 and R6 connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C9-13 (RE) - R6-1 (E) | Always | Below 1 Ω |
| C9-14 (VR) - R6-7 (RV) | Always | Below 1 Ω |
| R6-7 (RV) - Body ground | Always | 10 kΩ or higher |
| R6-1 (E) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||