POWER BACK DOOR DRIVE UNIT > INSPECTION |
| 1. INSPECT POWER BACK DOOR DRIVE UNIT |
![]() |
Connect the battery positive (+) lead to terminal 3 and battery negative (-) terminal lead to terminal 9.
Apply battery voltage to the terminals and check the motor operation.
| Measurement Condition | Specified Condition |
| Battery positive (+) →Terminal 7 Battery negative (-) → Terminal 8 | Open |
| Battery positive (+) →Terminal 8 Battery negative (-) → Terminal 7 | Close |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| 3 - 9 | 4.0 Ω |
Reinstall the unit with the connector connected.
![]() |
Reference:
Check the pulse of the pulse sensor.
Using an oscilloscope, check the pulse generated when the door is manually opened and closed.
| Terminal | 1 - 6, 5 - 6 |
| Tool setting | 10 V/DIV., 10 ms/DIV. |
| Vehicle condition | Door moving |