LIGHT CONTROL RHEOSTAT > INSPECTION |
| 1. INSPECT LIGHT CONTROL RHEOSTAT |
![]() |
Remove the light control rheostat with connector still connected.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| R6-1 (E) - R6-7 (RV) | Light control rheostat is in the MIN. position. | Below 1 Ω |
| R6-1 (E) - R6-7 (RV) | Light control rheostat is in the MAX. position. | 8 to 12 kΩ |
| R6-1 (E) - R6-7 (RV) | ODO/TRIP switch is OFF → ON | 10 kΩ or higher → Below 1 Ω |