ABS MAIN RELAY > INSPECTION

for Preparation Click here



1. INSPECT ABS MAIN RELAY (ABS NO.1 RELAY, ABS NO.2 RELAY)


    F047762E01
  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Specified Condition
    Terminal 1 - Terminal 2
    100 Ω
    Terminal 3 - Terminal 5
    10 kΩ or higher (No Continuity)

  1. Apply battery voltage between terminals 1 and 2.

  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Specified Condition
    Terminal 3 - Terminal 5
    Below 1 Ω