ABS MAIN RELAY > INSPECTION |
| 1. INSPECT ABS MAIN RELAY (ABS NO.1 RELAY, ABS NO.2 RELAY) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| Terminal 1 - Terminal 2 | 100 Ω |
| Terminal 3 - Terminal 5 | 10 kΩ or higher (No Continuity) |
Apply battery voltage between terminals 1 and 2.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| Terminal 3 - Terminal 5 | Below 1 Ω |