ABS MOTOR RELAY > INSPECTION

for Preparation Click here



1. INSPECT ABS MOTOR RELAY (ABS MTR1 RELAY, ABS MTR 2 RELAY)


    B057491
  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Connection
    Specified Resistance
    3 - 5
    Always
    10 kΩ or higher
    (No continuity)
    3 - 5
    Apply B+ between terminals 1 and 2
    Below 1 Ω