ABS MOTOR RELAY > INSPECTION |
| 1. INSPECT ABS MOTOR RELAY (ABS MTR1 RELAY, ABS MTR 2 RELAY) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Connection | Specified Resistance |
| 3 - 5 | Always | 10 kΩ or higher (No continuity) |
| 3 - 5 | Apply B+ between terminals 1 and 2 | Below 1 Ω |