EVAPORATOR TEMPERATURE SENSOR > ON-VEHICLE INSPECTION |
| 1. INSPECT A/C EVAPORATOR TEMPERATURE SENSOR |
Remove the A/C evaporator temperature sensor (A/C thermistor).
![]() |
Disconnect the connector from the A/C evaporator temperature sensor (A/C thermistor).
Measure the resistance according to the value(s) in the table below.

| Tester connection | Condition | Specified condition |
| 1 - 2 | -10°C (14°F) | 7.30 to 9.10 kΩ |
| 1 - 2 | -5°C (23°F) | 5.65 to 6.95 kΩ |
| 1 - 2 | 0°C (32°F) | 4.40 to 5.35 kΩ |
| 1 - 2 | 5°C (41°F) | 3.40 to 4.15 kΩ |
| 1 - 2 | 10°C (50°F) | 2.70 to 3.25 kΩ |
| 1 - 2 | 15°C (59°F) | 2.14 to 2.58 kΩ |
| 1 - 2 | 20°C (68°F) | 1.71 to 2.05 kΩ |
| 1 - 2 | 25°C (77°F) | 1.38 to 1.64 kΩ |
| 1 - 2 | 30°C (86°F) | 1.11 to 1.32 kΩ |