EVAPORATOR TEMPERATURE SENSOR > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT A/C EVAPORATOR TEMPERATURE SENSOR
  1. Remove the A/C evaporator temperature sensor (A/C thermistor).



    E112577E04
  1. Disconnect the connector from the A/C evaporator temperature sensor (A/C thermistor).



  1. Measure the resistance according to the value(s) in the table below.


    I036421E01

    Resistance:
    Tester connection
    Condition
    Specified condition
    1 - 2
    -10°C (14°F)
    7.30 to 9.10 kΩ
    1 - 2
    -5°C (23°F)
    5.65 to 6.95 kΩ
    1 - 2
    0°C (32°F)
    4.40 to 5.35 kΩ
    1 - 2
    5°C (41°F)
    3.40 to 4.15 kΩ
    1 - 2
    10°C (50°F)
    2.70 to 3.25 kΩ
    1 - 2
    15°C (59°F)
    2.14 to 2.58 kΩ
    1 - 2
    20°C (68°F)
    1.71 to 2.05 kΩ
    1 - 2
    25°C (77°F)
    1.38 to 1.64 kΩ
    1 - 2
    30°C (86°F)
    1.11 to 1.32 kΩ

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).