P0A72-326
Diagnostic trouble codes
DESCRIPTION
The MG ECU monitors the inverter current sensor. The ECU is for detecting a malfunction in the sensor lines and does not detect malfunctions in the high-voltage lines.| DTC No. |
INF Code |
DTC Detection Condition |
Trouble Area |
| P0A72 |
326 |
Malfunction in generator inverter current sensor (phase V sub sensor) |
|
| ↑ |
327 |
Open in generator inverter current sensor (phase V sub sensor) |
|
| ↑ |
328 |
Malfunction in generator inverter current sensor (phase V main sensor) |
|
| ↑ |
330 |
Open in generator inverter current sensor (phase V main sensor) |
|
| ↑ |
333 |
Performance problem of the generator inverter current sensor phase V |
|
| ↑ |
515 |
Malfunction in generator inverter current sensor (phase V main and sub sensors offset) |
|
| P0A75 |
334 |
Malfunction in generator inverter current sensor (phase W sub sensor) |
|
| ↑ |
335 |
Open in generator inverter current sensor (phase W sub sensor) |
|
| ↑ |
336 |
Malfunction in generator inverter current sensor (phase W main sensor) |
|
| ↑ |
338 |
Open in generator inverter current sensor (phase W main sensor) circuit |
|
| ↑ |
341 |
Performance problem of the generator inverter current sensor phase W |
|
| ↑ |
516 |
Malfunction in generator inverter current sensor (phase W main and sub sensors offset) |
|
MONITOR DESCRIPTION
The MG ECU monitors the generator inverter current sensor. If the HV control ECU detects a fault, it will illuminate the MIL and set a DTC.INSPECTION PROCEDURE
- CAUTION:
- Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from reconnecting it while you are working on the high-voltage system.
- After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals.
- Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from reconnecting it while you are working on the high-voltage system.
- HINT:
- At least 5 minutes is required to discharge the high-voltage capacitor inside the w/ converter inverter assembly.
| 1. CHECK CONNECTION CONDITION OF MG ECU CONNECTOR (LOOSENESS AND POOR CONTACT) |
- CAUTION:
- Be sure to wear insulated gloves.
Turn the ignition switch off and remove the service plug grip. (Click here)

- NOTICE:
- Do not put the vehicle into the READY-on state with the service plug grip removed as this may cause a malfunction.
Remove the inverter cover. (Click here)
- NOTICE:
- Wrap the interlock round terminal for the inverter cover with vinyl tape to prevent it from shorting to ground.
- Prevent water in the reservoir tank from entering the inverter.
- Removing the inverter cover causes the MG ECU board to be exposed. Therefore, temporarily install the inverter cover for each area to be inspected.
- Wrap the interlock round terminal for the inverter cover with vinyl tape to prevent it from shorting to ground.
Check the connections of the MG ECU connectors.
- Standard:
- Connectors are connected securely and there is no poor connection.
|
|
||||
| OK | ||
| ||