DATA LIST / ACTIVE TEST
System information
| DATA LIST |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on.
Operate the intelligent tester according to the steps on the display and select "Data List".
*1 NG (1): The steering angle sensor learning value has not been memorized completely./NG (2): Steering Angle Sensor Malfunction./NG (3): Communication Malfunction.Item
Item Description/Range (Display)
Inspection Condition
Reference Value
Torque Sensor 1 Output
Torque sensor 1 rotation angle/
Min.: 0 deg, Max.: 360 deg
Steering wheel is turned
Value changes from 0 to 360° every 45° of steering angle
Torque Sensor 2 Output
Torque sensor 2 rotation angle/
Min.: 0 deg, Max.: 360 deg
Steering wheel is turned
Value changes from 0 to 360° every 45° of steering angle
Meter Vehicle Velocity
Vehicle speed from meter/Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph)
- Vehicle is stopped
- Vehicle is driven at a constant speed
- 0 km/h (0 mph)
- No significant fluctuation
Engine Revolution
Engine revolution/Min.: 0 rpm, Max.: 8192 rpm
Engine is running at a constant speed
No significant fluctuation
Motor Actual Current
Amount of current to motor/Min.: -128 A, Max.: 127 A
Power steering is in operation
Value changes in proportion to steering effort
Command Value Current
Demanded amount of current to motor/Min.: -128 A, Max.: 127 A
Power steering is in operation
Value changes in proportion to steering effort
Steering Angle Velocity
Steering angle speed/Min.: -4096 deg/sec, Max.: 4064 deg/sec
Steering wheel is turned
Value changes in proportion to steering speed
Thermistor Temperature
ECU substrate temperature/Min.: -50 °C, Max.: 205°C
IG switch ON
-
PIG Power Supply
Power source voltage to activate motor/Min.: 0 V, Max.: 25.5 V
Power steering is in operation
10 to 14 V
IG Power Supply
ECU power source voltage/Min.: 0 V, Max.: 25.5 V
IG switch ON
10 to 14 V
TRQ1 Zero Point Value
Zero point value of torque sensor 1/Min.: 0 deg, Max.: 360 deg
Steering wheel is not turned
(without load)
Values differ depending on vehicle
TRQ2 Zero Point Value
Zero point value of torque sensor 2/Min.: 0 deg, Max.: 360 deg
Steering wheel is not turned
(without load)
Values differ depending on vehicle
Steering Wheel Torque
Steering torque/Min.: -7.0 N*m, Max.: 7.0 N*m
Steering wheel is turned
Value changes in proportion to steering effort
Motor Rotation Angle
Motor rotation angle/Min.: 0 deg, Max.: 360 deg
Steering wheel is turned
Value changes from 0 to 360° every 45° of steering angle
Command Val Current 2
Demanded amount of current to motor 2/Min.: -128 A, Max.: 127 A
-
-
Motor Voltage
Motor power source voltage/Min.: 0 V, Max.: 64 V
Power steering is in operation
27 to 51 V
Motor Terminal Volt (U)
Motor terminal voltage (U phase)/Min.: 0 V, Max.: 64 V
Power steering is in operation
2 to 51 V
Motor Terminal Volt (V)
Motor terminal voltage (V phase)/Min.: 0 V, Max.: 64 V
Power steering is in operation
2 to 51 V
Motor Terminal Volt (W)
Motor terminal voltage (W phase)/Min.: 0 V, Max.: 64 V
Power steering is in operation
2 to 51 V
Steering Angle Sens Sig
Steering angle sensor signal status/OK, NG (1), NG (2) or NG (3) (*1)
-
-
Battery Voltage
Battery voltage/Min.: 0 V, Max.: 25 V
IG switch ON
10 to 14 V
DRDD Voltage
Power source voltage to power steering converter/ Min.: 0 V, Max.: 25 V
IG switch ON
10 to 14 V
HV Battery Voltage
HV battery voltage/ Min.: 0 V, Max.: 510 V
IG switch ON
150 to 430 V
Power Source OK Sig
Power source OK signal/OK or NG
IG switch ON
OK
Break Gate Request Sig
Break gate request signal/OK or Break
IG switch ON
OK
DC-DC Warning Signal
Power steering converter warning signal/OK, NG (1), NG (2) or STOP (*2)
IG switch ON
OK
PS Assist Signal
Power steering assist signal/ON or OFF
IG switch ON
OK
Motor Overheat Record
Continuous overheat prevention control record/Rec or Unrec
-
-
Motor Lo Power Record
PIG power source voltage drop record/Rec or Unrec
-
-
Eng Rev Inter Record
Record of engine revolution signal interruption/Rec or Unrec
-
-
Str Angle Inter Record
Record of steering angle sensor signal interruption/Rec or Unrec
-
-
Spd Sig Invalid Record
Record of vehicle speed signal invalid/Rec or Unrec
-
-
Control Mode
Codes indicating DTC detection timing during ECU control are displayed in hexadecimal
-
-
IG ON/OFF Times
Number of times IG switch is turned on after DTC detection/Min.: 0 time, Max.: 255 times
-
-
The Number of DTCs
Number of detected DTCs when freeze frame data is stored/Min.: 0, Max.: 255
-
-
ECU Identification
ECU identification information/04
-
-
Test Mode Status
Selected mode/NORMAL or TEST
-
-
Ready Status
Ready status/OFF or Ready
-
-
*2 NG (1): DC-DC Converter has an internal failure./NG (2): DC-DC Converter has an external failure.- Vehicle is stopped