B1160/83
Diagnostic trouble codes
DESCRIPTION
The curtain shield squib RH circuit consists of the center airbag sensor assembly and the curtain airbag assembly RH.The circuit instructs the SRS to deploy when deployment conditions are met.
DTC B1160/83 is recorded when a short circuit is detected in the curtain shield squib RH circuit.
| DTC No. |
DTC Detecting Condition |
Trouble Area |
| B1160/83 |
|
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. CHECK CURTAIN SHIELD AIRBAG ASSEMBLY RH (CURTAIN SHIELD SQUIB RH) |
Turn the ignition switch to the LOCK position.

Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the connectors from the curtain shield airbag assembly RH.
Connect the white wire side of SST (resistance 2.1 Ω) to the floor wire.
- CAUTION:
- Never connect a tester to the curtain shield airbag assembly RH (Curtain shield squib RH) for measurement, as this may lead to a serious injury due to airbag deployment.
- NOTICE:
- Do not forcibly insert the SST into the terminals of the connector when connecting.
- Insert the SST straight into the terminals of the connector.
- SST
- 09843-18060
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Clear the DTCs stored in memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Check the DTCs (Click here).
- OK:
- DTC B1160/83 is not output.
- HINT:
- Codes other than DTC B1160/83 may be output at this time, but they are not related to this check.
|
|
||||
| OK | ||
| ||
| 2. CHECK CONNECTORS |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the SST (resistance 2.1 Ω) from the floor wire.
Check that the floor wire connectors (on the curtain shield airbag assembly RH side) are not damaged.
- OK:
- The lock button is not disengaged, and the claw of the lock is not deformed or damaged.
|
|
||||
| OK | |
| 3. CHECK FLOOR WIRE (CURTAIN SHIELD SQUIB RH CIRCUIT) |
Disconnect the connector from the center airbag sensor assembly.

Release the activation prevention mechanism built into connector "B" (Click here).
Measure the resistance according to the value(s) in the table below.
- Resistance:
Tester connection
Condition
Specified condition
C16-1 (ICR+) -
C16-2 (ICR-)
Always
1 MΩ or higher
|
|
||||
| OK | |
| 4. CHECK CENTER AIRBAG SENSOR ASSEMBLY |
Connect the connectors to the curtain shield airbag assembly RH and the center airbag sensor assembly.

Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Clear the DTCs stored in memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Check the DTCs (Click here).
- OK:
- DTC B1160/83 is not output.
- HINT:
- Codes other than DTC B1160/83 may be output at this time, but they are not related to this check.
|
|
||||
| OK | ||
| ||