FAIL-SAFE CHART
System information
| Condition |
Response |
Recovery |
| Engine coolant temperature data is interrupted for 5 seconds. |
The gauge needle indicates below "°C". |
Engine coolant temperature data is received. |
| Condition |
Response |
Recovery |
| "P" to "D" data is interrupted for 3 seconds. |
All indicator lights go off. |
Normal data is received. |
| "B" data is interrupted for 3 seconds. |
The "B" indicator light goes off. |
Normal data is received. |
| Condition |
Response |
Recovery |
| ABS & brake data is interrupted for 3 seconds. |
The warning light comes on. |
Normal data is received. |
| Condition |
Response |
Recovery |
| Regular data is interrupted. |
The data received most recently remains indicated. |
Normal data is received. |
| Condition |
Response |
Recovery |
| P/S data is interrupted for 3 seconds.. |
The indicator light comes on. |
Normal data is received. |
| Condition |
Response |
Recovery |
| Regular data is interrupted. |
The data received most recently remains indicated. |
Normal data is received. |
| Condition |
Response |
Recovery |
| Regular data is interrupted. |
The indicator light goes off. |
Normal data is received. |
| Condition |
Response |
Recovery |
| Airbag data is interrupted for 10 seconds or there is a malfunction in the combination meter (meter CPU). |
The warning light comes on. |
Normal data is received. |
| Condition |
Response |
Recovery |
| The illumination data is interrupted for 10 seconds or abnormal data is received. |
The display remains in daytime mode. |
Normal data is received. |
| Condition |
Response |
Recovery |
| Cruise information data is interrupted for 60 seconds. |
The display becomes blank (only measurement units displayed). |
Normal data is received. |
| Energy flow data is interrupted for 2 seconds. |
The energy flow display becomes blank. (Cursor does not appear.) |
Normal data is received. |
| The battery data is interrupted for 2 seconds. |
The display before receiving the data is displayed. |
Normal data is received. |