RX400h · Service Manual ENGINE

INSTALLATION

Removal / installation


1. INSTALL VVT SENSOR (for Bank 1)

  1. A079541E01
    Apply a light coat of engine oil to the O-ring on the VVT sensor (Bank 1).

  1. Install the VVT sensor (Bank 1) with the bolt.

    Torque:
    8.0 N*m{ 82 kgf*cm , 71 in.*lbf }

  1. Connect the VVT sensor (Bank 1) connector.


2. INSTALL VVT SENSOR (for Bank 2)

  1. A078529E01
    Apply a light coat of engine oil to the O-ring on the VVT sensor (Bank 2).

  1. Install the VVT sensor (Bank 2) with the bolt.

    Torque:
    8.0 N*m{ 82 kgf*cm , 71 in.*lbf }

  1. Connect the VVT sensor (Bank 2) connector.

  1. A108296E01
    Install the heated oxygen sensor connector (Bank 2) to the wire harness bracket.


3. INSTALL AIR CLEANER CAP W/ INLET
  1. Install the air cleaner filter element to the air cleaner case.

  1. A108124
    Install the 2 bolts, 4 clamps and air cleaner cap w/ inlet.

    Torque:
    7.0 N*m{ 71 kgf*cm , 62 in.*lbf }


4. INSTALL COOL AIR INTAKE DUCT SEAL
  1. Install the 4 clips and cool air intake duct seal.

← INSPECTIONPARTS LOCATION →