INSTALLATION
Removal / installation
| 1. INSTALL VVT SENSOR (for Bank 1) |
Apply a light coat of engine oil to the O-ring on the VVT sensor (Bank 1).

Install the VVT sensor (Bank 1) with the bolt.
- Torque:
- 8.0 N*m{ 82 kgf*cm , 71 in.*lbf }
Connect the VVT sensor (Bank 1) connector.
| 2. INSTALL VVT SENSOR (for Bank 2) |
Apply a light coat of engine oil to the O-ring on the VVT sensor (Bank 2).

Install the VVT sensor (Bank 2) with the bolt.
- Torque:
- 8.0 N*m{ 82 kgf*cm , 71 in.*lbf }
Connect the VVT sensor (Bank 2) connector.
Install the heated oxygen sensor connector (Bank 2) to the wire harness bracket.

| 3. INSTALL AIR CLEANER CAP W/ INLET |
Install the air cleaner filter element to the air cleaner case.
Install the 2 bolts, 4 clamps and air cleaner cap w/ inlet.

- Torque:
- 7.0 N*m{ 71 kgf*cm , 62 in.*lbf }
| 4. INSTALL COOL AIR INTAKE DUCT SEAL |
Install the 4 clips and cool air intake duct seal.