Operating Light Control Rheostat does not Change Light Brightness
Circuit diagnosis
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE OF INTELLIGENT TESTER |
Operate the intelligent tester according to the steps on the display and select "DATA LIST".
METER Item
Measurement Item/Range (Display)
Normal Condition
Diagnostic Note
Light Control Rheostat
Light control rheostat / Min.: 0, Max.: 255
Light control rheostat switch is Dark (0) → Bright (255)
-
- OK:
- Light brightness can be changed within the specified range by actual operation.
|
|
||||
| OK | ||
| ||
| 2. INSPECT LIGHT CONTROL RHEOSTAT |
Remove the light control rheostat with connector still connected.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
R6-1 (E) - R6-7 (RV)
Rheostat knob is in the MAX. position
8 to 12 kΩ
R6-1 (E) - R6-7 (RV)
Rheostat knob is in the MIN. position.
Approx. 0 Ω
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (BETWEEN COMBINATION METER AND LIGHT CONTROL RHEOSTAT) |
Disconnect the C9 and R6 connectors.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
C9-13 (RE) -
R6-1 (E)
Always
Below 1 Ω
C9-14 (VR) -
R6-7 (RV)
Always
Below 1 Ω
R6-7 (RV) -
Body ground
Always
10 kΩ or higher
R6-1 (E) -
Body ground
Always
Below 1 Ω
|
|
||||
| OK | ||
| ||