Back Door Opener Switch Circuit
Circuit diagnosis
DESCRIPTION
The back door opener switch only turns on while the back door handle is being pulled, and turns off when the handle is released.The body ECU is connected to the back door opener switch via terminal BDSU and back door unlatch operation request signals are input to the ECU.
The body ECU applies voltage to the back door opener switch via terminal BDSU. When the switch is on (there is continuity between the switch terminals), a back door unlatch operation request signal is input to the body ECU.
w/o Power back door system:
The body ECU directly activates the motor built into the back door lock assembly to unlatch the back door.
w/ Power back door system:
The body ECU, using multiplex communication, sends signals input from the back door operation switch to the power back door ECU. The power back door ECU then activates the motor built into the back door lock assembly to unlatch the back door based on the signals.
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE OF DATA LIST (BACK DOOR OPENER SWITCH) |
Check the DATA LIST to ensure proper function of the power back door opener switch.
Body ECU: Item
Measurement Item /
Display (Range)
Normal Condition
Diagnostic Note
Back Door Open SW
Back door opener switch signal (Outside handle switch)
/ON or OFF
ON: Back door opener switch is pushed
OFF: Back door opener switch is not pushed
-
- OK:
- The display is as specified in the normal condition.
|
|
||||
| OK | ||
| ||
| 2. INSPECT BACK DOOR OPENER SWITCH ASSEMBLY |
Remove the back door opener switch assembly.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Switch Position
Specified Condition
1 - 2
Free
10 kΩ or higher
1 - 2
Pushed
Below 1 Ω
|
|
||||
| OK | |
| 3. CHECK WIRE HARNESS (BACK DOOR OPENER SWITCH - INSTRUMENT PANEL J/B (BODY ECU)) |
Disconnect the back door opener switch assembly connector.

Disconnect the instrument panel J/B connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
P10-2 - B7-3 (BDSU)
Always
Below 1 Ω
P10-1 - Body ground
Always
Below 1 Ω
|
|
||||
| OK | ||
| ||