RX400h · Service Manual ENGINE

INSPECTION

Inspection


INSPECT A/F RELAY

  1. B016200
    Using an ohmmeter, measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    3 - 5
    10 kΩ or higher
    3 - 5
    Below 1 Ω (Apply battery voltage between terminals 1 and 2)

    If the result is not as specified, replace the relay.