INSPECTION
Inspection
| INSPECT LIGHT CONTROL RHEOSTAT |
Remove the light control rheostat with connector still connected.

Measure the resistance according to the value(s) in the table below.

Standard Resistance Tester Connection
Condition
Specified Condition
R6-1 (E) - R6-7 (RV)
Light control rheostat is in the MIN. position.
Below 1 Ω
R6-1 (E) - R6-7 (RV)
Light control rheostat is in the MAX. position.
8 to 12 kΩ
R6-1 (E) - R6-7 (RV)
ODO/TRIP switch is OFF → ON
10 kΩ or higher →
Below 1 Ω
- HINT:
- If the value is not as specified, replace the light control rheostat.