INSPECTION
Inspection
| INSPECT ABS MAIN RELAY (ABS NO.1 RELAY, ABS NO.2 RELAY) |
Measure the resistance according to the value(s) in the table below.

- Resistance:
Tester Connection
Specified Condition
Terminal 1 - Terminal 2
100 Ω
Terminal 3 - Terminal 5
10 kΩ or higher (No Continuity)
Apply battery voltage between terminals 1 and 2.
Measure the resistance according to the value(s) in the table below.
- Resistance:
Tester Connection
Specified Condition
Terminal 3 - Terminal 5
Below 1 Ω