P0AA4-228
Diagnostic trouble codes
DESCRIPTION
Refer to the description for DTC P0AA1-224. (Click here)| DTC No. |
INF Code |
DTC Detection Condition |
Trouble Area |
| P0AA4 |
228 |
Open or +B short in SMR3 (CON3) circuit |
|
| P0AA5 |
229 |
Short to GND in the SMR3 (CON3) circuit |
|
MONITOR DESCRIPTION
The HV control ECU monitors the proper operation of the system main relay No.3 (CON3). If the HV control ECU detects an open or short malfunction of the relay circuit, the HV control ECU illuminates the MIL and sets a DTC.WIRING DIAGRAM
See the wiring diagram of P0AA1-224. (Click here)INSPECTION PROCEDURE
- CAUTION:
- Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from reconnecting it while you are working on the high-voltage system.
- After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals.
- Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from reconnecting it while you are working on the high-voltage system.
- HINT:
- At least 5 minutes is required to discharge the high-voltage capacitor inside the w/ converter inverter assembly.
| 1. CHECK HARNESS AND CONNECTOR (HV CONTROL ECU - HV RELAY ASSEMBLY) |
- CAUTION:
- Be sure to wear insulated gloves.
Turn the ignition switch off and remove the service plug grip. (Click here)

- NOTICE:
- Do not put the vehicle into the READY-on state with the service plug grip removed as this may cause a malfunction.
Disconnect the H30 connector from the HV control ECU.
Disconnect the relay connector from the HV relay assembly.
Measure the voltage according to the value(s) in the table below when the ignition switch is in the ON position.
- HINT:
- If the ignition switch is turned to the ON position with the service plug grip removed, the DTC (P0A0D-350) for the interlock switch system will be output.
- Standard Voltage:
Tester Connection
Specified Condition
CON3 (H30-1) - Body ground
Below 1 V
Turn the ignition switch off.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for open):
Tester Connection
Specified Condition
CON3 (H30-1) - CON3 (S48-2)
Below 1 Ω
- Standard Resistance (Check for short):
Tester Connection
Specified Condition
CON3 (H30-1) or CON3 (S48-2) - Body ground
10 kΩ or higher
|
|
||||
| OK | |
| 2. INSPECT HV RELAY ASSEMBLY |
- CAUTION:
- Be sure to wear insulated gloves.
Turn the ignition switch off and remove the service plug grip. (Click here)

- NOTICE:
- Do not put the vehicle into the READY-on state with the service plug grip removed as this may cause a malfunction.
Remove the HV relay assembly from the vehicle. (Click here)
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Specified Condition
S49-1 - S45-1
Below 1 Ω
(Apply auxiliary battery voltage between terminals CON3 (S48-2) and GND (S48-4))
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Specified Condition
CON3 (S48-2) - GND (S48-4)
20 to 60 Ω
at -35 to 80°C ( -22 to -176°F)
|
|
||||
| OK | ||
| ||